MC-II
Plus
WP-PM Flow Analyzer
May 2005
23
Setting Flow Rate Filter
The flow rate filter smoothes out sudden changes in the rate indication and 4-20 mA
rate output due to variations in flow meter frequency. In all cases, the display will still
update once per second.
Although the 4-20mA rate output function is not applicable to the MC-II
Plus
Portable
Rate Meter, the user can achieve a smoother display of rate data by setting the flow
rate filter.
The degree of filtering is set by accessing the
rAtE.dLY
selection in the calibration
menu. It is located just after the
rAtE.EnG
selection.
From the
rAtE.dLY
selection, you may choose any of four filter settings, as
described below.
Display Setting
nonE
Filter disabled –
factory default setting
5
Time equal to 5 rate samples to reach 90% of final value
10
Time equal to 10 rate samples to reach 90% of final value
20
Time equal to 20 rate samples to reach 90% of final value
The
nonE
setting disables the filter. At this setting, the calculated flow rate tracks the
input frequency so any variation in the meter frequency will produce the correspond-
ing variation in the rate indication and 4-20 mA rate output.
Each subsequent setting of
5, 10
and
20
will dampen the signal, resulting in an
increasingly smooth display of changes in the meter frequency.
The steps required to change flow rate filtering on a calibrated unit are:
1. Enter the Calibrate Mode by pressing the
ACCESS
key.
2. Accept the current settings by pressing
ENTER
until the
rAtE.dLY
prompt is
displayed.
3. Press
INCR
or
STEP
until the desired flow rate filter is shown on the lower line
of the display. Press
ENTER
.
4. At this point, the flow rate filtering has been configured. Pressing
ACCESS
exits
the Calibrate Mode without making any further changes, or the remaining steps
may be implemented.
Setting Input Sensitivity
The input sensitivity of the MC-II
Plus
Flow Analyzer is measured in millivolts (mV)
peak-to-peak. This is the threshold value at which the circuitry responds to a signal.
Содержание MC-II Plus Panel Mount
Страница 41: ...Appendix A1 MC II Plus WP PM Flow Analyzer May 2005 A1 7 Dimensions in inches mm MC II Plus DIN Panel Mount...
Страница 44: ...MC II Plus WP PM Flow Analyzer Appendix A1 A1 10 May 2005 Flow Meter Input Wiring...
Страница 46: ...MC II Plus WP PM Flow Analyzer Appendix A1 A1 12 May 2005 External Power Wiring...
Страница 47: ...Appendix A1 MC II Plus WP PM Flow Analyzer May 2005 A1 13 4 4 to 20mA Rate Output Wiring...
Страница 49: ...Appendix A1 MC II Plus WP PM Flow Analyzer May 2005 A1 15 Reset Input with Power Supply and Reset Switch...
Страница 50: ...MC II Plus WP PM Flow Analyzer Appendix A1 A1 16 May 2005 Reset Using MC II Plus Battery and Reset Switch...
Страница 52: ...MC II Plus WP PM Flow Analyzer Appendix A1 A1 18 May 2005...
Страница 60: ...MC II Plus WP PM Flow Analyzer Appendix A2 A2 8 May 2005 Remote Mount Mounting Dimensions Horizontal Pole Mount...
Страница 62: ...MC II Plus WP PM Flow Analyzer Appendix A2 A2 10 May 2005...
Страница 65: ...Appendix C MC II Plus WP PM Flow Analyzer May 2005 C 1 Appendix C MC II Plus WP PM Configuration Menu Flowchart...
Страница 67: ...Appendix C MC II Plus WP PM Flow Analyzer May 2005 C 3 Appendix C MC II Plus WP PM Configuration Menu Flowchart...
Страница 68: ...MC II Plus WP PM Flow Analyzer Appendix C C 4 May 2005 Appendix C MC II Plus WP PM Configuration Menu Flowchart...
Страница 69: ...Appendix C MC II Plus WP PM Flow Analyzer May 2005 C 5 Appendix C MC II Plus WP PM Configuration Menu Flowchart...
Страница 70: ...MC II Plus WP PM Flow Analyzer Appendix C C 6 May 2005 Appendix C MC II Plus WP PM Configuration Menu Flowchart...
Страница 71: ...Appendix C MC II Plus WP PM Flow Analyzer May 2005 C 7 Appendix C MC II Plus WP PM Configuration Menu Flowchart...
Страница 72: ...MC II Plus WP PM Flow Analyzer Appendix C C 8 May 2005 NOTES...
Страница 78: ...MC II Plus WP PM Flow Analyzer Appendix D D 6 May 2005 NOTES...
Страница 92: ......