MC-II
Plus
WP-PM Flow Analyzer
May 2005
19
spare parts list. The divisor, divisor decimal point, rate multiplier, and rate multiplier
decimal point must be determined, then entered directly into the MC-II
Plus
Flow
Analyzer. The divisor is calculated as follows:
(
)
(
)
2
Fpv
Ts
Pa
Pg
CON
Tf
Ps
FC
Divisor
×
×
+
×
×
×
=
Where:
FC = Meter factor in pulses per actual cubic foot (PACF)
Ps = Standard pressure in PSIA
Tf = Average flowing temperature in degrees Rankine (
°
R)
CON
= Conversion factor for number of standard cubic feet (SCF) per unit volume of
desired measure.
Pg
=
Average flowing pressure in PSIG
Pa = Atmospheric pressure in PSIA
Ts = Standard temperature in degrees Rankine (
°
R)
Fpv = Average Supercompressibility Factor (enter a factor of 1 if supercompressibility
factor is not known)
The formula for calculating the rate multiplier is:
Divisor
TC
lier
RateMultip
=
TC
= Time Constant (seconds per unit time)
Normally used time constants are:
Units/minute rate,
TC
=
60
Units/hour rate,
TC
=
3600
Units/day rate,
TC
=
86400
An outline of the user prompts and the steps followed for this type of calibration are
below:
1. Press the
ACCESS
key to enter the Calibrate Mode.
2. At the prompt
tot Eng
, press
INCR
to select
USEr
. Press
ENTER
.
3. At the prompt
tot d.P
, press
INCR
to change the decimal point position for the
volume.
Press
ENTER
.
Содержание MC-II Plus Panel Mount
Страница 41: ...Appendix A1 MC II Plus WP PM Flow Analyzer May 2005 A1 7 Dimensions in inches mm MC II Plus DIN Panel Mount...
Страница 44: ...MC II Plus WP PM Flow Analyzer Appendix A1 A1 10 May 2005 Flow Meter Input Wiring...
Страница 46: ...MC II Plus WP PM Flow Analyzer Appendix A1 A1 12 May 2005 External Power Wiring...
Страница 47: ...Appendix A1 MC II Plus WP PM Flow Analyzer May 2005 A1 13 4 4 to 20mA Rate Output Wiring...
Страница 49: ...Appendix A1 MC II Plus WP PM Flow Analyzer May 2005 A1 15 Reset Input with Power Supply and Reset Switch...
Страница 50: ...MC II Plus WP PM Flow Analyzer Appendix A1 A1 16 May 2005 Reset Using MC II Plus Battery and Reset Switch...
Страница 52: ...MC II Plus WP PM Flow Analyzer Appendix A1 A1 18 May 2005...
Страница 60: ...MC II Plus WP PM Flow Analyzer Appendix A2 A2 8 May 2005 Remote Mount Mounting Dimensions Horizontal Pole Mount...
Страница 62: ...MC II Plus WP PM Flow Analyzer Appendix A2 A2 10 May 2005...
Страница 65: ...Appendix C MC II Plus WP PM Flow Analyzer May 2005 C 1 Appendix C MC II Plus WP PM Configuration Menu Flowchart...
Страница 67: ...Appendix C MC II Plus WP PM Flow Analyzer May 2005 C 3 Appendix C MC II Plus WP PM Configuration Menu Flowchart...
Страница 68: ...MC II Plus WP PM Flow Analyzer Appendix C C 4 May 2005 Appendix C MC II Plus WP PM Configuration Menu Flowchart...
Страница 69: ...Appendix C MC II Plus WP PM Flow Analyzer May 2005 C 5 Appendix C MC II Plus WP PM Configuration Menu Flowchart...
Страница 70: ...MC II Plus WP PM Flow Analyzer Appendix C C 6 May 2005 Appendix C MC II Plus WP PM Configuration Menu Flowchart...
Страница 71: ...Appendix C MC II Plus WP PM Flow Analyzer May 2005 C 7 Appendix C MC II Plus WP PM Configuration Menu Flowchart...
Страница 72: ...MC II Plus WP PM Flow Analyzer Appendix C C 8 May 2005 NOTES...
Страница 78: ...MC II Plus WP PM Flow Analyzer Appendix D D 6 May 2005 NOTES...
Страница 92: ......