4.0 ELECTRICAL INSTALLATION

For good EMC engineering practice, any sensor cables or switched 
live cables should not be placed within 50mm of other cables or on 
the same metal cable tray as other cables.

The electrical connection of the unit must be carried out by a 
qualified electrician. 

The unit is supplied with a flexible cord for connection to the mains 
supply.

4.1 Electrical Information

Electrical details:

Voltage: 240V  1ph  50Hz

Consumption: 1.2 Amp 

This unit must be earthed.

The cable from the mains power supply should be connected to a 
fixed wiring installation, via a fused isolator, in accordance with 
current IEE wiring regulations.

 
 

Supply    Supply    Extract    Extract

Speed1   Speed2    Speed1    Speed2

14 

PCB Details

Wiring is for reference purposes only as the connections in Figure 
14 are factory fitted.  The unit is pre-wired with a 2 metre fly lead.

4.2 Wiring Diagrams

4.2.1 Unit Serving Kitchen & Bathroom

Optional Controls - 

For further information regarding optional controls, contact Nuaire on 02920 858 400.

Disconnection from the 
supply mains must be 
incorporated within the 
fixed wiring in accordance 
with the wiring 
regulations and shall 
have a minimum contact 
separation  of 3mm.

3A Fuse

(BS 1362)

MAINS

230V

50Hz

Light

Room

Light

Switch

(Double

 Pole) 

N

L

3 Pole

Isolator

Kitchen Switch

Blue

Brown

Black

Optional 3 Speed Switch

Supply Cord 
From Unit

Grey

Green / Yellow

15 

Wiring Diagram - Kitchen & Bathroom

4.2.2 Unit Serving Kitchen & 2 Bathrooms

Disconnection from the 
supply mains must be 
incorporated within the 
fixed wiring in accordance 
with the wiring 
regulations and shall 
have a minimum contact 
separation  of 3mm.

3A Fuse

 (BS 1362)

MAINS

230V

50Hz

Room

Lights

Light

 Switches

 (Double

 Pole)

N

L

3 Pole

Isolator

Kitchen Switch

Blue

Green / Yellow

Brown

Black

Supply Cord 
From Unit

Optional 3 Speed Switch

Grey

16 

Wiring Diagram - Kitchen & Bathroom

Содержание MRXBOXAB-ECO2B-AE

Страница 1: ...een given supervision or instruction concerning the safe use of the appliance by a person responsible for their safety Children shall not play with the appliance Cleaning and user maintenance shall not be carried out by children 1 1 Hazard Symbols REFER TO INSTRUCTION MANUAL Read and understand the installation and maintenance manual before installing operating or maintaining this product 1 2 Impo...

Страница 2: ...TION Installation must be carried out by competent personnel in accordance with the appropriate authority and conforming to all statutory governing regulations All mains wiring must be in accordance with the current I E E Regulations or the appropriate standards Ensure that the mains supply Voltage Frequency and Phase complies with the rating label Please allow a minimum of 350mm in front of the e...

Страница 3: ...ple Collar 9 Condensate Drain MVHR DRAIN Condensate Drain Uninsulated Drain Pipe With Min 5 Fall Running To SVP 3 2 1 Solid Wall Mounting Recommended The MVHR unit fixed to a solid wall construction using the mounting bracket provided Ducting in the ceiling void Side view of unit mounted on the block wall in a cupboard using MVHR DRAIN the wall brackets Condensate drain uninsulated drain pipe with...

Страница 4: ...he BS5440 series of British Standards deals with this issue and currently states that an air intake must be at a minimum distance of 300mm from a gas boiler balanced flue Installers are advised to be aware of the requirements of this standard when installing through the wall supply air ducting 3 6 Ventilation Flow Rates 3 6 1 ADF 2010 Extract Ventilation Rates Room Min high rate Min low rate Kitch...

Страница 5: ...t very high moisture levels are likely to occur Therefore it is advisable that if the installation and building works are complete the unit is left running If the building works are not complete please close the air valves or cover up the air valves to prevent condensation forming in the ductwork and the MRXBOX95 unit due to natural migration of warm air 3 9 Dimensions 11 Dimensions 706 1 1 6 448 ...

Страница 6: ...ain pipe with min 5 o fall running to SVP Insulated extract duct 12 Typical Ducted Arrangement For A Wall Mounted Unit Using Circular Ducting 3 10 2 Rectangular Ducting Exhaust air from kitchen bathroom to outside via air brick Minimum distance as specified in building regulations Intake air from outside via air brick All duct between MVHR unit and atmosphere to be insulated Insulated supply duct ...

Страница 7: ...nly as the connections in Figure 14 are factory fitted The unit is pre wired with a 2 metre fly lead 4 2 Wiring Diagrams 4 2 1 Unit Serving Kitchen Bathroom Optional Controls For further information regarding optional controls contact Nuaire on 02920 858 400 Disconnection from the supply mains must be incorporated within the fixed wiring in accordance with the wiring regulations and shall have a m...

Страница 8: ...e unit will boost to that set by the commissioned boost speed The set point can be found behind the front panel of the unit Figure 17 and is at its least sensitive when turned fully clockwise The sensor is measuring humidity from all the wet rooms at the same time and should not be relied on to solely boost the unit Additional switch should be used local to the wet rooms Section 4 2 Adjustment onl...

Страница 9: ...nternational Sales office for further details Failure to maintain the unit as recommended will invalidate the warranty 9 0 END OF LIFE AND RECYCLING Where possible Nuaire use components which can be largely recycled when the product reaches its end of life Fans motors controls actuators cabling and other electrical components can be segregated into WEEE recycling streams Sheet metal parts aluminiu...

Страница 10: ...10 15 12 21 Document Number 671985 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO2B AE D Installation Manual NOTES ...

Страница 11: ...11 15 12 21 Document Number 671985 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO2B AE D Installation Manual NOTES ...

Страница 12: ...12 15 12 21 Document Number 671985 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO2B AE D Installation Manual NOTES ...

Отзывы: