background image

25 

16.2 - ARRANGING the WOOD EFFECT

 - 

continued

 

 
 
 

e). Fit the Left Centre Wood Piece 
     by Locating the Lugs On the Underside 
     of the Wood as shown. 

 
 

 
 
 
 
 
 
 
 

f). Fit the Right Centre Wood Piece by  
    Locating the Lugs On the Underside of 
    the Wood into the Recesses as shown. 

 
 
 
 
 
 
 
 
 

g). Fit the Centre Wood Piece by  
     Locating the Lugs On the Underside 
     of the Wood into the Recesses  
     as shown. 

  
 
 
 
 

                               

Finally adjust the Wood Pieces to ensure they are located correctly and stable.

 

 

h). Before fitting the glass panel with the 5 special countersunk screws and screw driver provided, check the condition of the 
     glass and ensure it is free from cracks or chips. 
 

NOTE: BEFORE FITTING THE GLASS PANEL IF A CONTEMPORARY TRIM IS TO BE FITTED THEN THE CURVED DÉCOR TRIM  
            WILL HAVE TO BE FITTED - SEE 15.1b 

 

                                                 

Most Important: Ensure it is clean and free of any finger marks.  

 
 
 

 

 

Содержание Fenton Balanced Flue

Страница 1: ...be placed close to or on the fire We recommend that a Fireguard conforming to BS8423 should be used for protection of Young Children the Elderly Infirm and Pets ALL INSTRUCTIONS MUST BE LEFT WITH THE...

Страница 2: ...rmity 32 23 Diagram of Infrared Control System 33 Guarantee 34 BOX CONTENTS The Fire comes in a number of boxes Box 1 Large box contains the Fire the Matrix Tray chosen Control System plus Fitting Kit...

Страница 3: ...mm copper pipe gas supply to the burner via the isolation elbow 1 2 050mm length of 5mm x 4mm self adhesive silicone sealing strip for around the frame and base of the fire 1 1 820mm length of 5mm x 4...

Страница 4: ...no nearer than 300mm to an opening in the building fabric formed for the purpose of accommodating a built in element such as a window frame The reference to external corners does not apply to building...

Страница 5: ...a Safety Pressure Relief System and if the fires ignition should ever become delayed or noisy then the fire MUST NOT be used until checked by a Qualified Engineer Installer t In the event that the fi...

Страница 6: ...y law and CE approval Commands are accepted by the microprocessor when buttons are pressed An audible beep means that the command has been received and the push button should immediately be released t...

Страница 7: ...l Flame button to set the Minute Press Off or simply wait to return to the manual screen IMPORTANT For the following modes of controlling the fire automatically for Temperature or Timer Programs the F...

Страница 8: ...ty alkaline e To change the Handset battery slide open the plastic panel on the back of the Handset f To change the Receiver Batteries remove the Ash Pan Cover and locate the electronic receiver box u...

Страница 9: ...ners IMPORTANT NOTE The Fire MUST NEVER be used without the Glass Panel in place or if it is in any way damaged 4 SERVICING a The fire should be Serviced Annually in accordance with the Gas Safety Use...

Страница 10: ...to comply with the above could leave the Installer Liable to Prosecution and Invalidate the Warranty IMPORTANT BEFORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY THESE INSTRUCT...

Страница 11: ...he left of the centre of the fire and 39mm up from the base of the Fireplace Builders opening An isolation elbow is provided at the control inlet Your 8mm gas supply pipe needs to protrude through the...

Страница 12: ...Construction Shelf Details Sections 11 12 13 are for the various Installation Applications for Traditionally Built Houses Only one will apply For Timber Frame Houses refer to Section 13 IMPORTANT NOTE...

Страница 13: ...nd high humidity so it is very important that any rendering building work is allowed to thoroughly dry out before installation NOTE Take Care Not To Use Materials That Will Give Off An Odour When Hot...

Страница 14: ...E INTERNAL WALLS e g Timber Wood Stud With or Without a Standard Rebated Fire Surrounds Back Panel or Slips 700mm Min 300 mm Min Flue Hole 160mm Dia Plaster Board Cut Back 25mm Around Flue Hole 454mm...

Страница 15: ...t is very important that any rendering building work is allowed to thoroughly dry out before installation NOTE Take Care Not To Use Materials That Will Give Off An Odour When Hot As This Issue Is Know...

Страница 16: ...Installation d Installation MUST take account of the Outer Wall Cladding be it Brick or Weather Boards the latter being combustible will require different Installation Requirements We recommend seeki...

Страница 17: ...STIBLE MATERIALS AND SHELVES a A non combustible shelf can be fitted above the fire and should be positioned at least 95mm above the builders opening We recommend the depth of the shelf should be a ma...

Страница 18: ...terial from inside the Flue d With the flue at the correct length and when the fire is fitted there should be 130mm of Flue Terminal Outside The Wall and the screw holes for fixing the Wall Plate shou...

Страница 19: ...e drill the lower holes 27mm up from the base and drill the higher holes 510mm up from the base see Cable Fixing Diagrams on next page Secure the 4 Eyebolts supplied with the Rawl Plugs to the back of...

Страница 20: ...t the Burner Assembly and secure with 4 screws reposition the Thermatronic Receiver Box and Infrared Sensor or for High Level Control the Battery Box onto their Velcro Pads if applicable Reposition Re...

Страница 21: ...ear Matrix on top of the Matrix Tray Ensure it is sat up against the back and with TOP facing you c Slide the Front Matrix in front of the burner as shown with FRONT facing you Health Safety Advice Re...

Страница 22: ...shown b Fit the Front Coal Cluster on top of the Front Matrix as shown c Fit 3off C coals up against the Rear of the fire as shown Set the C indent facing the back d Fit 2off B coals in the pocket in...

Страница 23: ...ls to ensure they are located correctly stable and not overhanging the pockets Also ensure non of the identification letters stamped on the coals are visible j Before fitting the glass panel with the...

Страница 24: ...Wood Coal Cluster on top of the Rear Matrix as shown b Fit the Front Wood Coal Cluster on top of the Rear Matrix as shown c Fit the Far Left Wood Piece into the Recessed area as shown d Fit the Far R...

Страница 25: ...e Underside of the Wood into the Recesses as shown Finally adjust the Wood Pieces to ensure they are located correctly and stable h Before fitting the glass panel with the 5 special countersunk screws...

Страница 26: ...d For Customers who have purchased the Thermatronic or High Level Controls explain and demonstrate that the batteries in the receiver and handset Thermatronic or Battery Box High Level should be repl...

Страница 27: ...5 special countersunk screws p With the 2 Remote Control Systems Always exchange the Batteries in both the Handset and Receiver q With the 2 Remote Control Systems ensure they are operational with th...

Страница 28: ...Disconnect the push on wire connections at the control Remove the switch and wires and replace with a new component in reverse order g All Control Systems have a Pressure Test Point to allow the Burne...

Страница 29: ...portant Note in Section 18 under Testing Commissioning Use d Fumes can be coming specifically from inferior Fire Surround materials e g resins from conglomerate materials which we do not recommend rat...

Страница 30: ...be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame Limited Model Fent...

Страница 31: ...must be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame Limited Model...

Страница 32: ...ton Balanced Flue Certificate Number 19GR0277 00 The object of the declaration described above is in conformity with relevant harmonized legislation Gas Appliance Regulation EU 2016 426 The following...

Страница 33: ...33 23 DIAGRAM OF RADIO FREQUENCY CONTROL SYSTEM...

Страница 34: ...uring the return delivery to us We will not be liable for any such breakages Under no circumstances should any attempt be made to repair the burner on site without our express knowledge and approval d...

Отзывы: