9
3. - CLEANING THE FIRE
Note: Marks on the Glass Panel are Not Covered by the Manufactures Warranty.
a.
Important
: Always Allow the fire to cool before carrying out any cleaning.
b. Please Note
: The glass panel surface within the room will be marked by air borne particles as air circulates through the fire
from the room, this is quite normal and cannot be prevented.
So the glass surface within the room can be cleaned with proprietary glass cleaners and any residue removed and dried afterwards.
No
Abrasive Cleaners Must be used.
c.
Within the fire it is quite normal for soot and stains to build-up on the inside of the glass panel, this is why we advise that the glass
panel must be fully cleaned during the Annual Service, however you can remove the glass panel for cleaning as follows:
i. Remove the Case by opening the Control Door and using the screw driver provided remove the 2 screws as shown. Now lift the Case
at the back clear of the fire and lay it down in a safe area.
ii. Using the Screw Driver provided remove the 5 Special Countersunk Screws then Ease the Glass/Frame Assembly outward slightly
at the base then Pull down and remove.
iii. To clean the glass panel use proprietary glass cleaners, however for stubborn stains use ‘T Cut Original’ and following treatment
remove all residue and polish with a dry cloth.
Note: The glass is etched with the Nu-Flame logo ensure it is at the bottom right hand corner when refitting the glass panel.
Note: It is Very Important to lay the Case down on its back as it can easily Fall Over and be damaged.
d.
The outer surfaces of the stove case can be cleaned with a damp cloth and lightly polished with a duster, do
not
use abrasive cleaners.
! IMPORTANT NOTE !
The Fire
MUST NEVER
be used without the Glass Panel in place or if it is in any way damaged.
4. - SERVICING
a.
The fire should be Serviced Annually in accordance with the Gas Safety & Uses Regulations.
b.
This fire contains no User Serviceable Parts apart from batteries (only used with the Thermatronic Control System option).
c.
Servicing must be carried out by a Registered Installer.
d.
For Servicing or Spare Parts contact your Installer quoting the Fire Name, Model and Serial Number, which can be found on the Data
Badge. To find the Data Badge/Plate; with the fire cool remove the Ash Pan, the Data Badge can be found at the base next to the
Control Knob.
e.
In the event that the fire shuts down due to any reason, attempt to restart it. If there is a continuing problem, call in a properly qualified
specialist engineer.
f.
Under No Circumstances
must this fire be used without the Glass Panel or if it is broken damaged or cracked.
g.
The Matrix in the fire is a Moulded Ceramic Fibre component incorporating Silicone Binders and you may notice that it develops
cracks during operation. This is natural shrinkage caused by exposure to high temperatures and is quite normal for the material and will
in no way affect the operation of the fire.
h.
The fire is fitted with a Safety Pressure Relief System and if the fires ignition should ever become delayed, or noisy then the fire
MUST
NOT
be used until checked by a Qualified Engineer/Installer.
i.
If at any time fumes are found to be emitting from the fire immediately turn the fire off.
Do not use and contact a Qualified Engineer/Installer.
RECORD DATA TO BE COMPLETED & KEPT BY USER:
IMPORTANT : THE FENTON BALANCED FLUE MUST ONLY BE REPAIED WITH Nu-Flame’s CE APPROVED PARTS
PLACE OF PURCHASE
..................................................................……………………
DATE
……....................
ADDRESS & TEL. NO.
…………….......................................…..................................................................................
.................................................................................................................................………………………..........….....
.................................................................................................................................………………………..........….....
APPLIANCE SERIAL NO.
..............................................
INSTALLED BY
........................................…………………………………
GAS SAFE REG. NO.
.........................
THE FENTON BALANCED FLUE