The Installation Applications Options Are:
11.0 Installation details for Traditional Built Houses with Internal Brick Walls.
12.0 Installation Houses with Internal Timber Stud Walls with Fire Surround & Shelf Details.
13.0 Installation into Timber Frame Housing.
11.1 - FIRE SURROUND APPLICATIONS
If a fire surround is being used we supply a Cable Fixing System as Drill Fixing may result in cracking of the back panel, which may not
show until the fire has got hot and then cooled down over a number of operations.
If the fire is being fitted against a Masonry Wall then the Fires Fixing Brackets with Drill/ Rawlplug Fixing Must be used and Not the Cable
Fixing System. See the Wall Fixing and Cable Fixing Diagrams on Page 20.
Nu-Flame does not recommend the use of a 1 piece back panel as cracking can occur.
Nu-Flame will not accept responsibility for Cracked Back Panels due to Drill Fixing.
Standard Fireplace Construction & Shelf Details
Sections 11, 12 & 13 are for the various Installation Applications for
Traditionally Built Houses - Only one will apply.
For Timber Frame Houses refer to Section 13
! IMPORTANT NOTE !
The chosen installation should have been
predetermined and arranged before installing the fire.
Ensure you refer to the Section relevant to your requirement.
11. - TRADITIONAL PROPERTY WITH NON COMBUSTIBLE INTERNAL WALLS (e. g. Brick)
With or Without a Standard & Rebated Fire Surrounds, Back Panel or Slips.
MASONRY FIREPLACE ENCLOSURE WITH
FLUE HOLE POSITION & SIZE
3 PIECE FIRE SURROUND BACK PANEL
NOTE: With Fire Surround Applications with Cable Fixing System
It may be necessary to rebate the heads of the eyebolts.
NOTE: When Fitted Against a Masonry Wall the Fires Fixing Brackets
Cavity Sealed Off
100mm away from
Flue
Combustible Shelf
Minimum Height
Non Combustible
Minimum Height
Hearth
160mm Min
Dia Flue Hole.
3 Piece
Fire Surround Back
Panel.
160mm Min
Dia Flue Hole.
Plaster Board Cut
Back 25mm
Around Flue
Dry Lined Internal
Walls with Cavity
635mm
Min
Minimum Flat Area
Around Flue
Upstand 15mm Max
630mm
Min