![NTI VEEMUX SM-nXm-C5AV-1000 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/nti/veemux-sm-nxm-c5av-1000/veemux-sm-nxm-c5av-1000_installation-and-operation-manual_1715183047.webp)
NTI VEEMUX AUDIO VIDEO MATRIX SWITCH VIA CAT5
42
Example of using Outputs Scanning Sequences
Problem
: A synchronous scan is desired for all outputs with a dwell time of 3 minutes per input, and no two outputs should be
looking at the same input at any given time.
Solution
:
1.
Set the dwell time for all inputs listed in each output at 180 seconds (3 minutes). Press “
Save
” each time changes are
made to the selected output. .
2.
Go to the Video Switch page (page 18) and set each output to an input of the same number (1 to 1, 2 to 2, 3 to 3, etc..).
Click on “
Submit
” at the bottom of the Video Switch Page to submit selections and establish a connection and starting
point for the scanning sequence. (Blocks shown in yellow in the third image indicate connections made.)
3.
Click on the “
Sequence Enable
” box for each output (from the Video Switch Page).
4.
Click on “
Submit
” again to begin the scanning sequence for each output.
From the moment the configuration is submitted, a synchronous scan will begin on all outputs. Each output will connect to its
respective input for 3 minutes. After 3 minutes, the outputs will each switch to the next consecutive input and remain connected
for 3 minutes. This cycle will continue indefinitely until sequencing is disabled.
Step 1- setup dwell times
Step 2- setup starting point for scan and click “Submit”
Step 3- enable scanning sequences and click “Submit”
Step 4- Click on “Submit” to begin