Ti Series Installation and Operation Instructions
│
Trinity
7
Swing Joint
to attain slope in
horizontal runs
Exhaust Vent
3”PVC, (check local
codes and Table 3-3)
Coupling -
3”PVC
Transition Piece
3” CPVC, minimum
5” long (factory
supplied)
Flue Outlet
Stainless Steel
Adapter (factory
supplied)
Air Inlet Adapter
Immediately
adapt from 1-
1/2”
to 3”
Cleanout
Recommended on
Air Inlet Piping
Figure 3-1(a)
Figure 3-1(b)
Near Boiler Venting (CPVC)
Near Boiler Venting (PVC)
Air-Inlet
- check with applicable local codes for acceptable pipe material.
Exhaust venting must be supported to reduce strain on piping joints. Failure to follow these instructions
may result in result in damage, serious injury or death.
In Canada, the first
3 ft (915 mm)
of vent piping must be readily accessible for inspection.
Table 3-2 Mandatory Vent Pipe Transition Piece
Model No.
CPVC Vent Pipe Size
CPVC Transition Vent Pipe Length
Full Insertion Depth
Trinity Ti100-200
3”
Minimum 5” [127 mm]
2-7/8” [73 mm]
Flue Outlet
Stainless Steel
Adapter (factory
supplied)
Swing Joint
to attain slope in
horizontal runs
Exhaust Vent
3”CPVC
Air Inlet Adapter
Immediately
adapt from 1-
1/2”
to 3”
Cleanout
Recommended on
Air Inlet Piping