Trinity
│
Installation and Operation Instructions
Ti Series
2
0.0 INTRODUCTION
General Installation Requirements
The installation of the NTI Trinity Ti gas boiler must conform to the requirements of this manual, your local authority, and the
National Fuel Gas Code ANSI Z223.1 and or CAN/CGA B149 Installation Codes. Where required by the Authority Having
Jurisdiction, the installation must conform to the standard for “Controls and Safety Devices for Automatically Fired Boilers
ANSI/ASME CSD-1.
This document pertains to the correct installation and operation of NTI Trinity Ti boiler models Ti100, Ti150 and Ti200. The
instructions detailed in this document supersede any and all previous
instructions provided by NTI, written or otherwise. Each
unit is provided with the following:
1)
Installation and Operation Instruction Manual for Trinity Ti Series,
2)
Trinity Users Manual and,
3)
Trinity Natural to LP Conversion Kit *
* The conversion kit is required to convert the appliance so it will safely operate with Propane Gas.
Read and understand this entire document prior to proceeding with the installation of the Trinity Ti.
Failure to follow instructions outlined in this document will result in property damage, injury or death.
User Responsibilities
This appliance must be installed and serviced by a qualified installer or service technician. This appliance must be serviced and
inspected annually when operating in normal residential applications. Demanding applications or extreme conditions (i.e.
commercial) may require more frequent service and inspection. As the User/Owner of this equipment, you are responsible for
ensuring the maintenance is performed at the required intervals. It is also the Users responsibility to ensure the Vent and
Combustion-Air Intake termination is kept clear of ice and snow or any other obstruction. Failure to follow these instructions
could result in fire, serious injury, or death.
Failure to have the appliance properly serviced and inspected on a regular basis may result in property
damage, serious injury or death.
Failure to keep the Vent and Combustion Air Intake clear of ice, snow, and other debris may result in
property damage, serious injury, or death.
Installer Responsibilities
As the installing technician it is your responsibility to ensure the installation is performed in accordance with this instruction
manual as well as any applicable local or National installation codes. It is also your responsibility to inform the User/Owner of
their obligation with respect to the above description under “User Responsibilities”. Failure to follow this warning could result in
fire, serious injury, or death.
ATTENTION: LIQUEFIED PETROLEUM (LP) PROPANE
The Trinity Ti is factory set to operate with Natural Gas. BEFORE OPERATING WITH PROPANE, the specified LP
Conversion Kit must be installed to convert the appliance so it will operate safely with LP Propane. Listed below is the
correct Natural to LP Propane Conversion Kit number for Trinity Ti100-200 boiler models. Note: kit number 82650-1
contains two LP conversion orifices. The smaller orifice, labeled 34, must be used in the Ti100, while the larger orifice,
labeled 52, must be used in the Ti150 and Ti200.
Liquefied Petroleum (LP) propane gas is heavier than air; therefore, it is imperative that your Trinity Ti boiler is not
installed in a pit or similar location that will permit heavier than air gas to collect. Local Codes may require appliances
fueled with LP gas be provided with an approved means of removing unburned gases from the room. Check your local
codes for this requirement.
Natural to LP Propane Conversion Kit
_
NTI Series
Model Number
Kit Number
Trinity Ti
100, 150, 200
82650-1
Failure to use the appropriate Natural to LP Conversion Kit when operating the Trinity Ti with Propane
will result in extremely dangerous burner operation leading to property damage, serious injury or death.
Refer to the above,
ATTENTION: LIQUEFIED PETROLEUM (LP) PROPANE
for correct conversion kit number.
Appliance Vent / Air-Intake Piping
The Trinity Ti is a “Direct Vent” appliance requiring a “Special Venting System”. Vent and
Combustion-Air Intake piping must be piped to the outdoors, using the vent material and rules outlined
in these instructions. Failure to follow instructions will result in serious injury or death.