Trinity Lx
│
Installation and Operation Instructions
Lx Series
74
Table 14-4 Alert Codes
Code
Description
Action/Response
329
Abnormal Recycle: Hardware invalid AC line
330
Abnormal Recycle: Hardware SLO flame ripple
331
Abnormal Recycle: Hardware SLO flame sample
332
Abnormal Recycle: Hardware SLO flame bias range
333
Abnormal Recycle: Hardware SLO flame bias heat
334
Abnormal Recycle: Hardware SLO spark stuck
335
Abnormal Recycle: Hardware SLO spark changed
336
Abnormal Recycle: Hardware SLO static flame
337
Abnormal Recycle: Hardware SLO rod shorted
338
Abnormal Recycle: Hardware SLO AD linearity
339
Abnormal Recycle: Hardware SLO bias not set
340
Abnormal Recycle: Hardware SLO bias shorted
341
Abnormal Recycle: Hardware SLO electronics
342
Abnormal Recycle: Hardware processor clock
343
Abnormal Recycle: Hardware AC phase
344
Abnormal Recycle: Hardware A2D mismatch
345
Abnormal Recycle: Hardware VSNSR A2D
346
Abnormal Recycle: Hardware 28V A2D
347
Abnormal Recycle: Hardware HFS IAS shorted
348
Abnormal Recycle: Hardware PII INTLK shorted
349
Abnormal Recycle: Hardware HFS LCI shorted
350
Abnormal Recycle: Hardware HFS LFS shorted
351
Abnormal Recycle: Invalid zero crossing
352
Abnormal Recycle: fault stack sensor
353
Abnormal Recycle: stack limit
354
Abnormal Recycle: delta T limit
355
Abnormal Recycle: fault outlet sensor
356
Abnormal Recycle: outlet high limit
357
Abnormal Recycle: fault DHW sensor
358
Abnormal Recycle: DHW high limit
359
Abnormal Recycle: fault inlet sensor
360
Abnormal Recycle: Check Parameters Failed
361
Internal error: No factory parameters were detected in control
362
Internal error: PID iteration frequency was invalid
363
Internal error: Demand-Rate interval time was invalid
364
Internal error: Factory calibration parameter for modulation was invalid
365
Internal error: CH PID P-scaler was invalid
366
Internal error: CH PID I-scaler was invalid
367
Internal error: CH PID D-scaler was invalid
368
Internal error: DHW PID P-scaler was invalid
369
Internal error: DHW PID I-scaler was invalid
370
Internal error: DHW PID D-scaler was invalid
371
Internal error: Lead Lag master PID P-scaler was invalid
372
Internal error: Lead Lag master PID I-scaler was invalid
373
Internal error: Lead Lag master PID D-scaler was invalid
374-
459 RESERVED
460
LCI demand lost in run
461
Demand lost in run
462
STAT demand lost in run