34
National Rejectors, Inc. GmbH, Buxtehude
T
ECHNICAL
DATA
8
Technical data
This chapter contains information about
•
all relevant hopper data
•
maximum capacities
•
the CE certification
•
the machine and empty/full interfaces
•
mounting dimensions
Device data
Supply voltage
12/24V DC, ± 10 %
Current consumption
Standby mode:
approx. 50 mA, ± 10 %
Inrush current, motor: approx. 3.5 A,
± 10 %
(for approx. 75 ms)
Coin payout
... with coins:
approx. 450 mA, ± 30 %
... without coins:
approx. 350 mA, ± 40 %
Electric strength
parallel: 13.2V at 12V; 26.4V at 24V
Inputs/outputs
ccTalk: ccTalk data voltage
Temperature range
Operating temperature: 5 °C up to 50 °C
Storage temperature:
-25 °C up to 70 °C
Temperature change
Max. 0.2 °C/min.
Rel. humidity
10 % up to 90 %
Condensation
Not permitted
Machine interface
10-pole terminal strip (standardized)
parallel:
1 control input (active low: 0V, inactive high: 5V)
1 coin output (open collector) (active low: 0V, inactive high:
5V)
1 error output (open collector) (active low: 0V, inactive
high: 5V)
ccTalk:
9600 baud, 8-bit, N, 1, 1, 5 V TTL, common transmitting
and receiving line, active low
Protocol according to ccTalk 4.2, Money Controls (see
section "Implemented ccTalk commands" in this chapter)
For pin assignment see section "Interfaces“ in this chapter
Содержание Currenza H2 Hopper Series
Страница 2: ......
Страница 6: ......
Страница 41: ...41 National Rejectors Inc GmbH Buxtehude TECHNICALDATA Top view Mounting dimensions h2 S View from the side ...
Страница 42: ...42 National Rejectors Inc GmbH Buxtehude TECHNICALDATA h2 M View from the side Top view ...
Страница 43: ...43 National Rejectors Inc GmbH Buxtehude TECHNICALDATA h2 L View from the side Top view ...