15
National Rejectors, Inc. GmbH, Buxtehude
D
ESIGN
Jumpers
Using the jumpers [2a/14] on the rear of the hopper (accessible by service
cover) you can bridge certain pins of the machine interface so that the
hopper works no longer in the parallel but in the ccTalk mode or vice versa
(see section "Configuring operating mode (parallel/ccTalk)“ in Chap. 6
"Operation").
Pilot lights
The three pilot lights [2a/7] on the rear of the hopper indicate the operating
state or a malfunction):
Green LED
Hopper is receiving control signal and activates
motor and payout disc (see Fig. 2c)
Yellow LED
Hopper is paying out coin and transmits coin signal
to control system
Red LED
Error (number of signals indicates error type, see
section "Troubleshooting" in Chap. 7 "Maintenance
and service")
Switching block
Using the switching block [2a/15] on the rear of the hopper (accessible by
service cover) you can change the operating mode (ccTalk/parallel) and the
ccTalk hopper address, if you want to provide the machine with several
hoppers (see sections "Configuring operating mode (parallel/ccTalk)" and
"Selecting ccTalk hopper address" in Chap. 6 "Operation").