LogBox-DA Datalogger 

NOVUS AUTOMATION 

6/7 

 

Fig. 15

 - General Information window

 

Acquisitions Table Window 

Here the data is presented in a table format, showing the date/time 
and the records values. 

 

Fig. 16

 – Screenshot showing the acquisitions table

 

MONITORING ACQUISITIONS 

To  visualize  current  measurements  in  a  graph  format,  use  the 

Monitor On-Line 

command by clicking on the button: 

 

While pointing the IR-LINK3 interface to the logger. 

 

 

Fig. 17

 – Online monitoring graph 

 

OBSERVATIONS 

The logger is an electronic device and some basic care is required: 

 

When  opening  the  device  for  battery  replacement  or  connecting 
sensors  avoid  touching  the  circuit  for  not  causing  damages 
resulting from static electricity. 

 

When the device is opened, avoid liquid and/or dust contact. 

 

Use  a  screwdriver  to  open  the  case  cover.  Pay  attention  to 
batteries  polarity: 

The  positive  terminal  should  be  placed 

directed towards the center of the device. 

 

Worn  batteries  should  not  be  recharged,  dismantled  or 
incinerated.  After  use,  batteries  must  be  disposed  according  to 
local legal rules or returned to Novus. 

 

After  placing  batteries  back  to  the  logger,  make  sure  the 
cover is firmly attached to the socket. 

MOST FREQUENTLY PROBLEMS 

The LED is not flashing.

 

The LED flashing light is intentionally weak, and it can be difficult to 
see it in illuminated environments. Make sure it is not flashing at all. 

Make sure the battery is installed correctly. 

Make sure the battery is not discharged. 

Communication with the logger fails

 

Make sure the COMM port is selected correctly and there is no other 
program using the same port during communication attempts. 

Make sure there is no physical obstacle blocking the infrared signal. 

Make sure the cable is well connected to the PC port. 

Make sure the port selected does not present any problem. 

ADDITIONAL INFORMATION 

If you have any doubt concerning this or other NOVUS products, e-
mail  us  at 

[email protected]

  or  visit  our  home  page: 

www.novus.com.br 

www.novusautomation.com

 

Содержание LogBox-DA

Страница 1: ...20mA 4 20mA 0 50mV or 0 5V user defined Note For the channel 2 depending on the input signal selected it may be necessary to configure an internal jumper DATA ACQUISITION LOGGING Data can be acquired by means of two different modes In channel 1 which counts pulses the number of input pulses counted in the logging time interval is stored in the logger memory at the end of the interval The maximum n...

Страница 2: ... the optical interface communication COM1 COM2 or USB CONFIGURING THE LOGGER Make sure the IR LINK3 wand is connected to the PC port selected The interface must be pointed towards the logger communication window see Fig 5 at a distance of about 15 cm Fig 5 Infrared interface position Click the button to start the communication between the logger and the software the Parameters Configuration window...

Страница 3: ... triggered Once activated the alarm LED indicator stays so even after the alarm triggering situation has ceased CHANNEL 2 ANALOG INPUT The options provided for Channel 2 configurations are Tag Defines a name up to 8 characters for identifying the variable to be measured Input The signal applied to the logger second input is defined here The following options are offered None disabled 4 20 mA 0 20 ...

Страница 4: ...he logger Note The case cover should not be opened unless battery replacement is required If this is the case the cover must be properly tightened back in its place such as to assure the IP67 68 protection Fig 9 IP67 external connectors Wire connections Channels cable right Connection Blue Channel 1 3 IN1 positive Black Channel 1 4 GND negative White Channel 2 1 IN2 positive Brown Channel 2 2 GND ...

Страница 5: ...logger during the process Data can be collected anytime and saved in files for future analysis menu File Save or File Save as While in offloading process a progress bar is displayed The offload time is proportional to the amount of data being transferred number of records in memory After data transfer is completed the Graph window is displayed NOTE The logging is not stopped during the data offloa...

Страница 6: ...rds the center of the device Worn batteries should not be recharged dismantled or incinerated After use batteries must be disposed according to local legal rules or returned to Novus After placing batteries back to the logger make sure the cover is firmly attached to the socket MOST FREQUENTLY PROBLEMS The LED is not flashing The LED flashing light is intentionally weak and it can be difficult to ...

Страница 7: ...mV 10 MΩ 0 10 Vdc 120 kΩ Memory capacity 64000 64k Interval between readings Minimum 1 second maximum 18 hours External battery switch time 0 to 10 s Power 3 6 V lithium battery 1 2 AA Estimated autonomy 200 days with one weekly download and 5 minutes measuring interval Battery life depends heavily on data retrieval frequency Working temperature From 40 C to 70 C Protection IP65 and IP67 models se...

Отзывы: