manualshive.com logo in svg
background image

HOBO®

 

MX2300

 

Series

 

Data

 

Logger

 

Manual

 

20923

K

 

The

 

HOBO

 

MX2300

 

series

 

data

 

loggers

 

record

 

and

 

transmit

 

temperature

 

and/or

 

relative

 

humidity

 

(RH)

 

in

 

outdoor

 

or

 

indoor

 

environments.

 

These

 

Bluetooth®

 

Low

 

Energy

enabled

 

loggers

 

are

 

designed

 

for

 

wireless

 

communication

 

with

 

a

 

mobile

 

device.

 

Using

 

the

 

HOBOmobile®

 

or

 

HOBOconnect®

 

app,

 

you

 

can

 

easily

 

configure

 

the

 

logger,

 

read

 

it

 

out,

 

and

 

view

 

data

 

on

 

your

 

phone

 

or

 

tablet,

 

or

 

export

 

the

 

data

 

for

 

further

 

analysis.

 

The

 

logger

 

can

 

calculate

 

minimum,

 

maximum,

 

average,

 

and

 

standard

 

deviation

 

statistics

 

and

 

be

 

configured

 

to

 

indicate

 

alarms

 

at

 

thresholds

 

you

 

specify.

 

The

 

logger

 

also

 

supports

 

burst

 

logging

 

in

 

which

 

data

 

is

 

logged

 

at

 

a

 

faster

 

interval

 

when

 

sensor

 

readings

 

are

 

above

 

or

 

below

 

certain

 

limits.

 

The

 

Temp

 

and

 

Temp/RH

 

models

 

have

 

internal

 

sensors

 

while

 

the

 

External

 

Temp/RH,

 

External

 

Temp,

 

and

 

2x

 

External

 

Temp

 

include

 

built

in

 

external

 

sensors,

 

offering

 

a

 

wide

 

range

 

of

 

solutions

 

for

 

monitoring

 

temperature

 

and

 

RH

 

in

 

numerous

 

applications.

 

Specifications

 

Temperature

 

Sensor

 

 

Range

 

MX2301A

 

and

 

MX2305

 

internal

 

sensors:

 ‐

40

 

to

 

70°C

 

(

40

 

to

 

158°F)

 

MX2302A

 

external

 

temperature

 

sensor:

 ‐

40

 

to

 

70°C

 

(

40

 

to

 

158°F)

 

MX2303

 

and

 

MX2304

 

external

 

sensors:

 ‐

40

 

to

 

100°C

 

(

40

 

to

 

212°F),

 

with

 

tip

 

and

 

cable

 

immersion

 

in

 

fresh

 

water

 

up

 

to

 

50°C

 

(122°F)

 

for

 

one

 

year

 

Accuracy

 

±0.25°C

 

from

 ‐

40

 

to

 

0°C

 

(±0.45

 

from

 ‐

40

 

to

 

32°F)

 

±0.2°C

 

from

 

0

 

to

 

70°C

 

(±0.36

 

from

 

32

 

to

 

158°F)

 

±0.25°C

 

from

 

70

 

to

 

100°C

 

(±0.45

 

from

 

158

 

to

 

212°F),

 

MX2303

 

and

 

MX2304

 

only

 

Resolution

 

MX2301A

 

and

 

MX2302A:

 

0.02°C

 

(0.036°F)

 

MX2303,

 

MX2304,

 

and

 

MX2305:

 

0.04°C

 

(0.072°F)

 

Drift

 

<0.01°C

 

(0.018°F)

 

per

 

year

 

Relative

 

Humidity

 

Sensor*

 

(MX2301A,

 

MX2302A

 

only)

 

Range

 

0

 

to

 

100%

 

RH,

 ‐

40°

 

to

 

70°C

 

(

40°

 

to

 

158°F);

 

exposure

 

to

 

conditions

 

below

 ‐

20°C

 

(

4°F)

 

or

 

above

 

95%

 

RH

 

may

 

temporarily

 

increase

 

the

 

maximum

 

RH

 

sensor

 

error

 

by

 

an

 

additional

 

1%

 

Accuracy

 

±2.5%

 

from

 

10%

 

to

 

90%

 

(typical)

 

to

 

a

 

maximum

 

of

 

±3.5%

 

including

 

hysteresis

 

at

 

25°C

 

(77°F);

 

below

 

10%

 

RH

 

and

 

above

 

90%

 

RH

 

±5%

 

typical

 

Resolution

 

0.01%

 

Drift

 

<1%

 

per

 

year

 

typical

 

Response

 

Time

 

(typical,

 

to

 

90%

 

of

 

change)

 

Temperature

 

Without

 

Solar

 

Radiation

 

Shield

 

With

 

RS1/M

RSA

 

Solar

 

Radiation

 

Shield

 

With

 

RS3

B

 

Solar

 

Radiation

 

Shield

 

 

MX2301A

  

internal

 

sensor

 

17

 

minutes

 

in

 

air

 

moving

 

1

 

m/sec

 

24

 

minutes

 

in

 

air

 

moving

 

1

 

m/sec

 

NA

 

 

MX2302A

  

external

 

sensor

 

3

 

minutes,

 

45

 

seconds

 

in

 

air

 

moving

 

1

 

m/sec

 

7

 

minutes,

 

45

 

seconds

 

in

 

air

 

moving

 

1

 

m/sec

 

6

 

minutes,

 

30

 

seconds

 

in

 

air

 

moving

 

1

 

m/sec

 

 

MX2303/MX2304

 

external

 

sensors

 

3

 

minutes

 

in

 

air

 

moving

 

1

 

m/sec;

 

20

 

seconds

 

in

 

stirred

 

water

 

7

 

minutes

 

in

 

air

 

moving

 

1

 

m/sec

 

4

 

minutes

 

in

 

air

 

moving

 

1

 

m/sec

 

 

MX2305

  

internal

 

sensor

 

17

 

minutes

 

in

 

air

 

moving

 

1

 

m/sec

 

24

 

minutes

 

in

 

air

 

moving

 

1

 

m/sec

 

NA

 

RH

 

Without

 

Solar

 

Radiation

 

Shield

 

With

 

RS1/M

RSA

 

Solar

 

Radiation

 

Shield

 

With

 

RS3

B

 

Solar

 

Radiation

 

Shield

 

 

MX2301A

  

internal

 

sensor

 

30

 

seconds

 

in

 

air

 

moving

 

1

 

m/sec

 

40

 

seconds

 

in

 

air

 

moving

 

1

 

m/sec

 

NA

 

 

MX2302A

  

external

 

sensor

 

15

 

seconds

 

in

 

air

 

moving

 

1

 

m/sec

 

30

 

seconds

 

in

 

air

 

moving

 

1

 

m/sec

 

30

 

seconds

 

in

 

air

 

moving

 

1

 

m/sec

 

 

 

HOBO

 

MX2300

 

Series

  

Data

 

Logger

 

Models:

 

 

MX2301A,

 

temp/RH

 

 

MX2302A,

 

ext

 

temp/RH

 

 

MX2303,

 

2

 

ext

 

temp

 

 

MX2304,

 

ext

 

temp

 

 

MX2305,

 

temp

 

Included

 

Items:

 

 

Screws

 

 

Cable

 

ties

 

Required

 

Items:

 

 

Mobile

 

device

 

with

 

Bluetooth

 

 

HOBOmobile

 

app

 

for

 

devices

 

with

 

iOS

 

 

HOBOconnect

 

app

 

for

 

devices

 

with

 

Android™

 

Accessories:

 

 

Solar

 

radiation

 

shield

  

(RS3

B

 

for

 

use

 

with

 

MX2302A,

 

MX2303,

 

and

 

MX2304

 

models;

 

RS1

 

or

 

M

RSA

 

for

 

use

 

with

 

MX2301A

 

and

 

MX2305

 

models)

 

 

Mounting

 

bracket

 

for

 

solar

 

radiation

 

shield

 

(MX2300

RS

BRACKET),

 

for

 

use

 

with

 

MX2301A

 

and

 

MX2305

 

models

 

 

Replacement

 

battery

  

(HRB

2/3AA)

 

 

 

Содержание HOBO MX2300 Series

Страница 1: ...C 40 to 158 F exposure to conditions below 20 C 4 F or above 95 RH may temporarily increase the maximum RH sensor error by an additional 1 Accuracy 2 5 from 10 to 90 typical to a maximum of 3 5 including hysteresis at 25 C 77 F below 10 RH and above 90 RH 5 typical Resolution 0 01 Drift 1 per year typical Response Time typical to 90 of change Temperature Without Solar Radiation Shield With RS1 M R...

Страница 2: ...luetooth Always On disabled Faster logging intervals and statistics sampling intervals burst logging remaining connected with the app excessive downloads and paging may impact battery life Memory MX2301A and MX2302A 128 KB 63 488 measurements maximum MX2303 MX2304 and MX2305 128 KB 84 650 measurements maximum Full Memory Download Time Approximately 60 seconds may take longer the further the device...

Страница 3: ...e app to connect to it If the logger does not appear or if it is having trouble connecting follow these tips Make sure the logger is awake by pressing the start button The alarm and status LEDs will blink once when the logger wakes up You can also press the button a second time to bring it to the top of the list if you are working with multiple loggers Make sure the logger is within range of your ...

Страница 4: ...t the next even interval as determined by the selected logging interval On Button Push Logging will begin once you press the button on the logger for 3 seconds On Date Time Logging will begin on a date and time you specify Select the date and time In HOBOmobile tap Done Tap Done or Save 8 Tap Stop Logging and select the options for when logging will end a Choose one of two memory options When Memo...

Страница 5: ...s 30 minute period 7 Tap Done or Save and repeat steps 3 6 for the other sensor if desired 8 In the configuration settings select one of the following options to determine how the alarm indications are cleared Logger Reconfigured The alarm indication will display until the next time the logger is reconfigured Sensor in Limits The alarm icon indication will display until the sensor reading returns ...

Страница 6: ...ults for the sampling period recorded at each logging interval The following statistics can be logged for each sensor The maximum or highest sampled value The minimum or lowest sampled value An average of all sampled values and The standard deviation from the average for all sampled values For example a logger is configured with both the temperature and RH sensors enabled and the logging interval ...

Страница 7: ...to view a larger version of the graph or share the file In HOBOconnect Tap the HOBO Files icon and select the file to view it Tap and then to export and share the data Data can also be uploaded automatically to HOBOlink Onset s web based software via the app or the MX gateway For details see the app user s guide and see the HOBOlink help for details on working with data in HOBOlink Logger Events T...

Страница 8: ...s 2 year typical with a logging interval of 1 minute but may be extended to 5 years when the logger is configured with Bluetooth Always On disabled Expected battery life varies based on the ambient temperature where the logger is deployed the logging or sampling interval frequency of offloading and connecting to the mobile device number of channels that are active and use of burst mode or statisti...

Страница 9: ...ircuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC C...