Operating manual
LTSA LTMA
Status message
Cause
Measure
5200 Home position
The applicator has not reached
its home position within the as-
signed time period.
5201 Touch down
The applicator has not reached
the product (touch down
position) within the set stroke
length
.
5203 Touch down sens. The touchdown sensor(s) was/
were already actuated before
the application process.
For all status messages
:
► Check whether the applicator can
move unhindered. If necessary, remove
any obstacles.
EXPERTS
► Check whether the cable(s) is/
are correctly connected.
EXPERTS
► Check whether the sensor(s)
is/are soiled.
EXPERTS
► Check whether the sensor(s)
is/are defective.
For 5203 Touch down sens.
:
► Check, if a product was available.
► Check, if the applicator has hit the
product.
Table 5: Overview: Status messages possibly caused by an applicator malfunction.
4
Setable by
Options
>
LTSA
>
Stroke length
Edition 02 - 7/2021
29
Operation / Malfunctions / Cleaning
Remedying malfunctions