Operating manual
LTSA LTMA
INSTALLING CONVERSION KIT LTMA IN XLP 514
Describes how a XLP 504 “Basic” with rewinder is converted into a XLP 514 for LTMA by installing the
“conversion kit LTMA”.
WARNING!
This machine operates at mains voltage. Contacting electrically live components can
cause lethal electrical shocks and burns!
► Only authorised technicians who are familiar with the associated hazards are per-
mitted to carry out conversion work on the printer!
► After assembly, check the machine according to the applicable regulations of the
relevant country (for Germany: DIN VDE 701-702 "Recurrent test and test after repair
and modification of electrical equipment").
Before you begin
Printer
: XLP 514 “Basic” with rewinder
Conversion kit
LTMA (N103133)
Tools
:
• Torx screwdriver T10, T20
• Open-ended spanner, size 5
Procedure
1.
Replace enclosure part (1) with enclosure part (2).
(4 screws Torx DG 40 x 10)
Edition 02 - 7/2021
18
Commissioning