Installing Business Continuity Clustering
41
no
vd
ocx
(e
n)
13
Ma
y 20
09
The container where the Server objects reside.
If Server objects reside in multiple containers, this must be a container high enough in the tree
to be above all containers that contain Server objects.
The best practice is to have all Server objects in one container.
The container where the cluster Pool objects and Volume objects are placed when they are
synchronized to this cluster. This container is referred to as the
landing zone
. The NCP
TM
Server
objects for the virtual server of a BCC-enabled resource are also placed in the landing zone.
The container where the User objects reside that need to be synchronized. Typically, the User
objects container is in the same partition as the cluster objects.
IMPORTANT:
Full eDirectory replicas are required. Filtered eDirectory replicas are not supported
with this version of Business Continuity Clustering software.
4.1.6 SLP
You must have SLP (Server Location Protocol) set up and configured properly on each server node
in every cluster. Typically, SLP is installed as part of the eDirectory installation and setup when you
install the server operating system for the server. For information, see
“Implementing the Service
Location Protocol” (http://www.novell.com/documentation/edir88/edir88/data/ba5lb4b.html)
in the
Novell eDirectory 8.8 Administration Guide
.
4.1.7 Identity Manager 3.5.1 Bundle Edition
The Identity Manager 3.5.1 Bundle Edition is required for synchronizing the configuration of the
peer clusters in your business continuity cluster. It is not involved in other BCC management
operations such as migrating cluster resources within or across peer clussters.
Before you install Business Continuity Clustering on the cluster nodes, make sure that Identity
Manager and the Identity Manager driver for eDirectory are installed on one node in each peer
cluster that you want to be part of the business continuity cluster.
The same Identity Manager installation program that is used to install the Identity Manager engine is
also used to install the Identity Manager eDirectory driver and management utilities. See
“Business
Continuity Cluster Component Locations” on page 38
for information on where to install Identity
Manager components.
“Downloading the Bundle Edition” on page 41
“Credential for Drivers” on page 42
“Identity Manager Engine and eDirectory Driver” on page 42
“Identity Manager Driver for eDirectory” on page 42
“Identity Manager Management Utilities” on page 42
Downloading the Bundle Edition
The bundle edition is a limited release of Novell Identity Manager 3.5.1 for NetWare 6.5 SP8 (same
as OES 2 SP1 NetWare) that allows you to use the Identity Manager software, the eDirectory driver,
and the Identity Manager management tools for Novell iManager 2.7.2. BCC driver templates are
applied to the eDirectory driver to create BCC-specific drivers that automatically synchronize BCC
Содержание BUSINESS CONTINUITY CLUSTERING 1.1 SP2 - ADMINISTRATION
Страница 4: ...4 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 10: ...10 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 26: ...26 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 36: ...36 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 54: ...54 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 82: ...82 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 92: ...92 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 122: ...122 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 126: ...126 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...