Setting Up Auto-Failover
C
133
no
vd
ocx
(e
n)
13
Ma
y 20
09
C
Setting Up Auto-Failover
Auto-failover is available beginning in Novell
®
Business Continuity Clustering 1.1. To set up the
auto-failover feature, you must enable it, then configure the auto-failover settings.
WARNING:
Auto-failover is disabled by default and is not recommended. It should only be
enabled after a thorough examination and review of your network and geographic site infrastructure.
You should seriously consider the adverse conditions that might occur as a result of enabling this
feature.
These conditions may include but are not limited to:
Data loss at one or more geographic sites
Data corruption at one or more geographic sites
Data divergence at one or more geographic sites
For example, if there is a loss of communication between two clusters and auto-failover has been
enabled and configured, each cluster will assert ownership of BCC-enabled cluster resources. These
resources then automatically load on both clusters.
When communication between cluster has been restored, some of the data on each cluster is
different. This is called data divergence. Also, the mirroring or synchronization process either fails,
or attempts to overwrite any changed data on one cluster. This causes either data loss or data
corruption.
Section C.1, “Enabling Auto-Failover,” on page 133
Section C.2, “Creating an Auto-Failover Policy,” on page 134
Section C.3, “Refining the Auto-Failover Policy,” on page 134
Section C.4, “Adding or Editing Monitor Configurations,” on page 136
C.1 Enabling Auto-Failover
To enable auto-failover for all Business Continuity Cluster resources in a cluster:
1
Start your Internet browser and enter the URL for iManager.
The URL is http://
server_ip_address
/nps/iManager.html. Replace
server_ip_address
with the
IP address or DNS name of the server that has iManager and the Identity Manager
preconfigured templates for iManager installed.
2
Specify your username and password, specify the tree where you want to log in, then click
Login
.
3
In the left column, click
Clusters
, then click the
Cluster Options
link.
4
Specify a cluster name, or browse and select the Cluster object.
5
Click the
Properties
button and then click the
Business Continuity
tab.
6
Click the
Main
link.
7
Click the
Auto-Failover
button.
Содержание BUSINESS CONTINUITY CLUSTERING 1.1 SP2 - ADMINISTRATION
Страница 4: ...4 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 10: ...10 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 26: ...26 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 36: ...36 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 54: ...54 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 82: ...82 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 92: ...92 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 122: ...122 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...
Страница 126: ...126 BCC 1 1 SP2 Administration Guide for NetWare 6 5 SP8 novdocx en 13 May 2009...