Table 11: Resolving an Error in the Receiver Status Word
Bit Set
Action to Resolve
0
Check the Error Word in the RXSTATUS log. See also
Table 10, Resolving a Receiver Error Word
1
Check temperature ranges in the ENVIRONMENTAL table sections Technical Specifications
starting on page 122
2
Section 2.4, Power Supply Requirements, page 24
3
Section 2.3, Selecting a GNSS Antenna, page 22
Section 2.3.1, Choosing a Coaxial Cable,
Section 2.3.3, Connecting the Antenna to the Receiver, page 24
4
5
6
7
Check the CPU idle time. Check for unnecessary logging. Check for simultaneous use of
functionality, for example, API and RTK
8
Table 7, Serial Ports Supported
9
10
11
15-17
Reserved
18
When the receiver has tracked GNSS satellites long enough for a valid almanac to be received,
this bit will be set to 0.
19
None. This bit only indicates if the receiver has calculated a position.
20
None. This bit is a status bit indicating if the receiver’s position has been manually fixed and does
not represent a problem. Refer also to the
FIX
command in the
OEM6 Family Firmware Reference
(OM-20000129)
21
None. This bit indicates if clock steering has been manually disabled. Refer also to the
FRESET
command in the
OEM6 Family Firmware Reference Manual
(OM-20000129)
22
None. This bit only indicates if the clock model is valid. Refer also to the
FRESET
command in the
OEM6 Family Firmware Reference Manual
(OM-20000129)
23
None. This bit indicates if the phase-lock-loop is locked when using an external oscillator. Refer
also to the
FRESET
command in the
OEM6 Family Firmware Reference Manual
(OM-20000129)
24
Check the CPU idle time. Check for unnecessary logging. Check for simultaneous use of
functionality, for example, API and RTK
29
None. This bit indicates if any bits in the auxiliary 3 status word are set. The auxiliary 3 word
provides status information and does not contain any new information on problems. Refer also to
the
FRESET
OEM6 Family Firmware Reference Manual
(OM-20000129)
30
None. This bit indicates if any bits in the auxiliary 2 status word are set. The auxiliary 2 word
provides status information and does not contain any new information on problems. Refer also to
the
FRESET
command in the
OEM6 Family Firmware Reference Manual
(OM-20000129)
31
None. This bit indicates if any bits in the auxiliary 1 status word are set. The auxiliary 1 word
provides status information and does not contain any new information on problems. Refer also to
the
FRESET
command in the
OEM6 Family Firmware Reference Manual
(OM-20000129)