4.8.6
Manual Log File Naming
Use NovAtel Connect or HyperTerminal to name logged files.
If the file name entered already exists, the command returns an error. Use the LOGFILESTATUS log to
view errors, determine if a log file is open or closed or if the internal storage device is busy.
4.8.6.1
Automatic Log File Naming
If a name is not supplied for a logged file, one is automatically generated based on the PSN of receiver
and an automatically incrementing number beginning at one. If a log in the sequence number is deleted,
the number is recycled for use in order.
4.8.7
Stop Logging
Issue the
LOGFILE CLOSE
command to end logging.
4.8.8
Reading Data and Post-Processing
Logs can be directed to any of the OEM638 communication ports and can be automatically generated
when new or changed data becomes available or at regular intervals. Data can be collected through
NovAtel Connect using the
Logging Control Window
.
Refer to the NovAtel Connect Help available from within the utility Help or the .chm file bundled with the
software comprehensive logging instructions.
4.8.9
Pass-Through Logging
The pass-through logging feature enables the GNSS receiver to redirect any ASCII or binary data that is
input at a specified COM port or USB port, to any specified receiver COM or USB port. This capability, in
conjunction with the
SEND
command, allows the receiver to perform bidirectional communications with
other devices such as a modem, terminal or another receiver.
There are several pass-through logs: PASSCOM1, PASSCOM2, PASSCOM3, PASSXCOM1,
PASSXCOM2, PASSXCOM3, PASSUSB1, PASSUSB2, PASSUSB3, PASSICOMX, PASSNCOM and
PASSAUX are available on OEM6 family receivers for logging through serial ports. Refer to the
PASSCOM logs in the
OEM6 Family Firmware Reference Manual
(OM-20000129) for details.
Refer to the