- 2 - 

REV-114

                                                                                                                            

NOVATEK-ELECTRO

 

 

 
 

WARNING! 

– PRODUCT TERMINALS AND INTERNAL COMPONENTS ARE UNDER POTENTIALLY 

LETHAL VOLTAGE. 
TO ENSURE THE PRODUCT SAFE OPERATION IT IS STRICTLY FORBIDDEN THE FOLLOWING: 

 

 

TO CARRY OUT MOUNTING WORKS AND MAINTENANCE WITHOUT DISCONNECTING THE PRODUCT 

FROM THE MAINS; 

 

TO OPEN AND REPAIR THE PRODUCT INDEPENDENTLY; 

 

TO OPERATE THE PRODUCT WITH MECHANICAL DAMAGES OF THE CASE. 

IT  IS  NOT  ALLOWED  WATER  PENETRATION  ON  TERMINALS  AND  INTERNAL  ELEMENTS  OF  THE 

PRODUCT. 

During operation and maintenance the regulatory document requirements must be met, namely: 
Regulations for Operation of Consumer Electrical Installations; 
Safety Rules for Operation of Consumer Electrical Installations; 
Occupational Safety in Operation of Electrical Installations; 
Installation,  adjustment  and  maintenance  of  the  product  must  be  performed  by  qualified  personnel  having 

studied this Operation Manual. 

The product is safe for use under keeping of the operating rules. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание REV-114

Страница 1: ...m of development and production production complies with the requirements of ISO 9001 2015 Dear Customer Company thanks you for purchasing our products You will be able to use properly the product aft...

Страница 2: ...OF THE CASE IT IS NOT ALLOWED WATER PENETRATION ON TERMINALS AND INTERNAL ELEMENTS OF THE PRODUCT During operation and maintenance the regulatory document requirements must be met namely Regulations...

Страница 3: ...e delay relay REV 114 is the microprocessor based device intended to control the load with independent time delay It provides the certain sequence of the load operation according to the mode specified...

Страница 4: ...17 Adjustment range of time from 0 1 s to 10 days Timing adjustment Buttons on the front panel Digit display of remaining time available Service of the product Switchgear and control gear Rated opera...

Страница 5: ...ed for set time and the indicator is on During the delay time the indicator periodically is off At the end of the delay time the load relay contacts are open and the product starts fulfillment of algo...

Страница 6: ...he indicator is off and the product goes into standby mode In case of repeated occurrence of the control signal S the algorithm fulfillment is repeated 8 Pulse I with external start After energizing t...

Страница 7: ...ith external start and on delay After energizing the indicator ON Fig 1 it 10 is on and the product goes into standby mode in this case the load relay contacts C and NO are open and the indicator Fig...

Страница 8: ...ts C and NO remain open and the indicator is off The product goes into the standby mode until power off 3 INTENDED USE 3 1 Preparation for operation Unpack the product we recommend to keep the origina...

Страница 9: ...nd wire can burn If you increase the tightening torque it is possible to have thread failure of the terminal block screws or the compression of the connected wire Error when performing the installatio...

Страница 10: ...is case the display will flash the current value of the selected time unit Using the buttons or set the required value Press the buttons one time to save the set value and return to the previous menu...

Страница 11: ...t should be packed in the original or other packing excluding mechanical damage You are kindly requested in case of return of the product and transfer it to the warranty post warranty service in the f...