Radio Frequency Function Option
80-9357-0110-020 Rev. A
7
Fail Secure / Fail Safe Electric Strike 24VDC Wiring
1
2
3
4
1
2
3
4
Optional Door 2
1
2
3
4
1
2
3
4
Door 1
ORANGE
BLACK
BROWN/WHITE
RED
RF
RECEIVER
BOARD
(PART OF
OPERATOR
UNIT)
WIRING FOR
MOMENTARY
HOLD OPEN
FUNCTION
Notes:
1. Power input to Door Operator Unit is at
“T1” Power Input Terminal (not shown)
120VAC 60Hz.
2. Radio Frequency Feature can be
purchased as a separate kit.
Operation:
Door is normally closed.
Activating wireless switch or hand held
wireless transmitter will open the door.
Door will close after hold open delay
elapses.
1
2
3
4
1
2
3
4
120VAC
Supplied by
Others
-
+
24VDC Out
24
VDC
Electr
ic
S
tr
ik
e
+
-
Wall Switch, Card
Reader, Key Switch,
etc.
Normally Open Momentary
dry contacts
Notes:
1. Power input to Door Operator Unit is at
“T1” Power Input Terminal (not shown)
120VAC 60Hz.
View of Jumper in
Normally Open
Position For Use With
“Fail Safe” Strike
View of Jumper in
Normally Closed
Position For Use With
“Fail Secure” Strike
Jumper
(top pin
open)
Jumper
(bottom pin
open)
Operation:
Door is normally closed and latched.
Activating switch will unlock the electric strike and
the door will automatically open. Door will close
after hold open time delay has elapsed.
- The door will remain
during power failure.
- The door will remain
during power failure.
For Fail Secure Strike
locked
For Fail Safe Strike
unlocked
Normally
Open
Relay
Normally
Closed
Relay
Ground
COM
HOT
120
VAC