Series 5710–Door Openings 85° to 110° or 111° to 180°
Rigid Arm and Slide Track Application
Maximum Hinge Side Frame Reveal to 1/8” (3mm)
Hinge (Pull) Side of Door Installation
80-9357-0110-020 Rev. A
80-9357-0110-020 Rev. A
WARNING
120 VOLT POTENTIAL PRESENT. MAKE SURE
POWER IS TURNED OFF DURING
INSTALLATION PROCEDURE.
An incorrectly installed or improperly
adjusted door operator can cause property
damage or personal injury. These
instructions should be followed to avoid the
possibility of misapplication or
misadjustment.
CAUTION
CAUTION
Right Hand Door
Left Hand Door
Left
Hand
Door
Right
Hand
Door
5700 LEO
Low Energy Power Operator
Installation Instructions
™
• U.L. labeled fire or smoke barrier door assemblies require that
the 120VAC (60Hz) power input to the
door operator be
supplied through normally closed alarm contacts of the alarm
system/alarm panel.
• Power input to
door operator must be 120 VAC (60Hz) to
terminals HOT and COM at terminal strip T1. Earthground
(GND) to green screw on Backplate.
• All wiring must conform to standard wiring practice in
accordance with national and local wiring codes.
• Note: Unless otherwise noted, all dimensions are given in
inches (millimeters).
• Minimum suggested and required material thickness for hollow
metal frames (skin plus reinforcement) is charted on Page 2.
• For wiring refer to Wiring Instructions on Pages 5 thru 8.
• Unit is Non-Handed.
• Door must be hung on butt hinges [5" (127mm) max. width] or
3/4" (19mm) offset pivots. A separate door and frame
preparation template will be supplied for other conditions.
• Door must swing freely through the entire opening and closing
cycle before beginning the installation.
• Use of a supplemental door stop is always recommended.
LEO
LEO
Requirements
Requirements
Installation Template
Component Layout
Installation Sequence
General Templating Information
Installation Sequence Continued
General Electrical Data
Input Power Configuration
Inverter Details
Wiring Diagram - Standard Function with Switches
Wiring Diagram - Optional Radio Frequency Function
Wiring Diagram - Fail Safe / Fail Secure Electric Strike
Wiring Diagram - Fail Safe Electromagnetic Lock
A.D.A / UL Information
1
2
2
3
3
4
5
5
6
6
7
7
8
8
1-1/2” (38mm)
Min. Frame
Face
Frame
Reveal
Door
6” (152mm)
Min. Ceiling
Clearance
1-3/4” (44mm) Min.
2-1/4” (57mm) Max.
Door Thickness