Chapter 1: eDrive Dimensions, Power Requirement, and Mounting
© 2017 Cutting Edge Optronics, Inc.
3
Patara-IR TEM
00
Laser Pre-Installation Guide
there are no configuration switches to set for high or low power ranging. Table 1-1 lists
the recommended fuse selection for each voltage range.
Table 1-1 Recommended Fuse Ratings
AC Input
Frequency
Fuse Ratings
(F1, F2)
120V ±10% 15A
50/60 Hz
T 15A 250V
240V ±10% 8A
50/60 Hz
T 8A 250V
Fuse Dimensions: 0.25 x 1.25 inches
Rack Mounting
When installing the eDrive Nitro into an EIA-310D-compliant rack, always install rack
mounting screws into the two bottom holes of the front panel flanges first and then install
screws into the top holes. This will help to minimize any potential damage that might
occur to the eDrive front panel if the driver were to shift during installation.
For the eDrive Nitro, it is recommended that two people install the unit into a rack.
Supporting rails should be used. Lift the driver into place and then fasten the front panel
flanges into place.
WARNING.
Using the eDrive Nitro without mounting rails can result in serious damage
to the driver or personal injury.
Clearance
Adequate clearance should be allowed on the front, sides, and rear of the eDrive for
access to connections and components. The front and rear vents of the eDrive must be a
minimum of 24 inches (61 cm) away from walls or vertical surfaces so air flow is not
restricted.
Weight
The total weight of eDrive Nitro for Patara laser is approximately 52 pounds (23.6kgs).