![Nortel SMC 2450 Скачать руководство пользователя страница 187](http://html1.mh-extra.com/html/nortel/smc-2450/smc-2450_implementation-manual_1706451187.webp)
The Command Line Interface (CLI)
Page 187 of 260
Secure Multimedia Controller
Implementation Guide
Enabling SSH
Before SSH access is possible, you must first configure the SMC to allow
SSH access.
Procedure 51
Enabling SSH using the CLI
1
Start a console terminal.
2
Press <Enter> on the console terminal to establish the connection.
Result:
The SMC login prompt appears.
3
Enter
admin
for the default login name.
4
Enter
admin
for the default password.
5
Check that the SMCs are configured with proper IP addresses.
6
Enable SSH access.
a.
Enter
/cfg/sys/adm/ssh/
ena
.
b.
Enter
apply
.
7
Generate new SSH keys.
During the initial setup of the SMC, Nortel recommends that you select the
option to generate new SSH host keys. This is required to maintain a high
level of security when connecting to the SMC using an SSH client. If you
fear that the SSH host keys are compromised, or at any time the security
policy dictates, you can create new host keys.
When reconnecting to the SMC after generating new host keys, the SSH
client displays a warning that the host identification (or host keys) is
changed.
a.
Enter
/cfg/sys/adm/ssh/gensshkey
.
b.
Enter
apply
.
8
Use the access list to permit remote access to trusted clients. See
“Defining the remote access list” on
page 89
.
Note:
By default, administration access is only allowed through the
management subnet. You need to add entries to the access list and then
enable the Web UI, SSH, and Telnet. Users can access management
only through the host IP address or the Master IP.
Содержание SMC 2450
Страница 2: ......
Страница 4: ...Page 4 of 260 Revision history 553 3001 225 Standard 1 00 May 2006...
Страница 10: ...Page 10 of 260 Contents 553 3001 225 Standard 1 00 May 2006 Format 251 Log message table 253...
Страница 16: ...Page 16 of 260 List of procedures 553 3001 225 Standard 1 00 May 2006...
Страница 20: ...Page 20 of 260 About this document 553 3001 225 Standard 1 00 May 2006...
Страница 27: ...Description Page 27 of 260 Secure Multimedia Controller Implementation Guide Figure 1 Basic subnet mappings...
Страница 51: ...Description Page 51 of 260 Secure Multimedia Controller Implementation Guide Figure 7 SMC campus redundancy...
Страница 56: ...Page 56 of 260 Description 553 3001 225 Standard 1 00 May 2006...
Страница 76: ...Page 76 of 260 Hardware installation 553 3001 225 Standard 1 00 May 2006...
Страница 120: ...Page 120 of 260 Firewall deployment 553 3001 225 Standard 1 00 May 2006...
Страница 126: ...Page 126 of 260 Secure UNIStim deployment 553 3001 225 Standard 1 00 May 2006 Figure 22 Sample policy page...
Страница 160: ...Page 160 of 260 Secure UNIStim deployment 553 3001 225 Standard 1 00 May 2006...
Страница 182: ...Page 182 of 260 Maintenance 553 3001 225 Standard 1 00 May 2006...
Страница 196: ...Page 196 of 260 The Command Line Interface CLI 553 3001 225 Standard 1 00 May 2006...
Страница 212: ...Page 212 of 260 Logging 553 3001 225 Standard 1 00 May 2006...
Страница 228: ...Page 228 of 260 Appendix C Regulatory information 553 3001 225 Standard 1 00 May 2006 DenAn regulatory notice for Japan...
Страница 250: ...Page 250 of 260 Appendix D Software licenses 553 3001 225 Standard 1 00 May 2006...
Страница 260: ...Page 260 of 260 Appendix E SMC packet filter log messages 553 3001 225 Standard 1 00 May 2006...
Страница 261: ......