![Nortel Meridian 1 Mini-Carrier Remote Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/nortel/meridian-1-mini-carrier-remote/meridian-1-mini-carrier-remote_description-installation-and-maintenance_1706402062.webp)
Page 62 of 150
Installation and configuration
P0914209
Standard 3.00
April 2000
Connecting cable assemblies to the LMI:
1
Connect P1 of the NT5D85 LMI Multi I/O cable, see Figure 5 on page
17, to the 50-pin Amphenol connector for the first of the two line card
slots occupied by the LMI.
2
Connect P1 of the NT5D86 LMI/LMX multi-I/O cable assembly, see
Figure 6 on page 18, to the 50-pin Amphenol connector for the second of
the two line card slots occupied by the LMI.
3
Refer to the following when installing the NT7R87BA T1 CSU cable kit
to connect the T1 carriers from the LMI or RMI to the CSU.
•
Connect the NT7R93BA adapter to P2 (carrier 0) or P3 (carrier 1) of the
LMI or RMI I/O cable.
•
Connect the 32’ span cable to the NT7R93BA adapter.
30
0
1
1
1
1
31
1
1
1
1
1
—end—
Table 10 (Continued)
LMI maintenance daisy chain addresses
LMI
Address
SW2 at U23 positions 1-5 (1 = ON, 0 = OFF)
1
2
3
4
5