Installation and configuration
Page 57 of 150
Mini-Carrier Remote
Description, Installation, and Maintenance
Figure 11
Jumper settings on MCR circuit packs.
1
Set the DIP switches to specify the distance to the CSU, the MMI
terminal baud and daisy-chain address. The DIP switch settings outlined
in Table 6 “LMI SW2 at U23 functions,” and Table 7, “LMI SW3 at U51
functions,” will depend on the physical system configuration.
2
Pull the LMI locking devices away from the faceplate. Holding the card
by these locking devices, insert it into the card guides of the selected line
card slots.
3
Slide the card into the module until it engages in the backplane
connector.
4
Carefully push the locking device levers toward the faceplate to insert the
card connector into the backplane connector and lock the card in place.
5
The card LED should blink three times and then stay on until enabled by
software. When enabled by software, the card LED turns off
permanently, as long as the card is operational.
J 3
Not used
Jumper
installed
for LMI
Jumper
installed
for LMX
Jumper
installed
for RMI
E D G E O F F A C E P L A T E
(Top of card )