Page 110 of 150
Maintenance
P0914209
Standard 3.00
April 2000
Figure 55
DISPLAY STATUS DISTANT screen
The responses displayed on the screen show: the firmware version,
present time and date, individual carrier fault threshold parameters,
and the present status of each carrier link.
If a carrier-link mismatch exists, the status will display unequal alarm
levels across a mismatched link. To verify that carrier links are
connected correctly at both ends perform the tests in ”Verifying
mini-carrier links at the remote site,” on page 100, in the Description
chapter of this document.
3
Display the alarm log by executing the
DISPLAY ALARM (D A),
or
DISPLAY ALARM DISTANT (D A D)
commands. These
commands display the list of the most recent 100 alarms with the for
the near-end
(D A)
or distant end
(D A D)
locations along with
the date and time that each alarm occurred. Both screens are similar
to Figure 56.
Note: Invoking the
D A
and
D A D
commands display the alarm
log. To clear the alarm log, use the
CLEAR ALARM LOG (C A L)
and
CLEAR ALARM LOG DISTANT (C A L D)
commands.
Figure 56
DISPLAY ALARM (D A) screen
MCR::>d s d
MCR S/N Firmware Version V6.1C 14:56:26 03/17/98
Local Site:
Link 0 Alarm Level 0
Link 1 Alarm Level 0
LMX 0 S/N NNTM1831R0LV F/W V6.1C Status - NORMAL
LMX 1 S/N NNTM1831TE22 F/W V6.1C Status - NORMAL
LMX 2 S/N NNTM1831TE25 F/W V6.1C Status - NORMAL
MCR::>
MCR::>d a
Alarm Log
02/05/98 10:56:38 Log Cleared
MCR::>