Installation and configuration
Page 55 of 150
Mini-Carrier Remote
Description, Installation, and Maintenance
Note 1: The NT7R87BA T1 CSU Cable Kit provided with the MCR
equipment is used to connect the LMIs and RMIs to telco demarcation
points (CSUs) at a distance of 32 feet (9.75 m). Install this cable kit, if
applicable, between the CSU and the LMI at the local site and the RMI
at the remote site as a preinstallation procedure.
Note 2: Mini-Carrier Remote is not intended for direct connection to the
public switched network or other exposed plant networks. Always
connect this product to such networks through a certified (by local,
regional, or national safety agency and telecommunications authority),
isolating type network terminating device (CSU, DSU, NT1, NCTE, or
the like) that provides overvoltage protection.
Route twisted-pair wires for T1 carrier links from the telco demarcation point
to the MCR equipment. Use standard cable routing procedures to prevent
cable exposure to possible damage from contact with machine and human
traffic. Terminate the twisted-pair wires with an 8-pin modular plug.
Local site installation
•
Install and verify the operation of the Meridian 1 system, if not already
installed and operating correctly.
•
Identify the line card slots and install the LMI and LMXs in the system.
(The LMI and LMXs must all be in the same IPE shelf or Option 11
cabinet.)
•
Install the LMI/LMX cable.
•
Connect the LMI Multi-I/O cable assembly (NT5D85) to the SDI and
MMI ports, and the T1 carrier links.