Vibration endurance - transportation (packaged)
The MCR circuit packs retain full functionality after vibration endurance
testing according to IEC 68-2-6, Test Fc under the following conditions:
Frequency swept automatically from 5 Hz to 100 Hz at the rate of one octave
per minute with a constant acceleration of 0.5 g, repeated for 30 minutes on
each of the three mutually perpendicular axes.
Frequency swept automatically from 100 Hz to 200 Hz at the rate of one
octave per minute with a constant acceleration of 1.5 g, repeated for 30
minutes on each of the three mutually perpendicular axes
Vibration endurance - earthquake
The MCR circuit packs retain full functionality after the earthquake test
specified by Bellcore NEBS(TR-EOP 000063) for Zone 4, upper floor.
Electromagnetic compatibility
The LMI, RMI, and LMX circuit packs do not interfere with operation of
other licensed communications systems.
The LMI, RMI, and LMX circuit packs do not adversely effect the
compliance of the Meridian 1 system to Class A of FCC Part 15 Subpart B.
Electromagnetic immunity
The LMI, RMI, and LMX circuit packs in a Meridian 1 system resist
electromagnetic interference and comply with FCC. These circuit packs
perform correctly when subjected to narrow band, radiated fields in a
frequency range between 500 kHz and 1 GHz (field strength up to 5 V/m, 1
kHz, 50% modulated AM signal). The MCR circuit packs conform to
EN500082-1 and IEC 801 standards for EMC immunity.
Electrostatic discharge
The LMI, RMI, and LMX circuit packs are immune to electrostatic
discharges typical for an office environment (carpeted floors, low humidity)
using the test method specified by IEC 801-2.
The LMI, RMI, and LMX circuit packs withstand, without malfunction, a
direct discharge of up to +/-15kV(to user accessible surface and face plate).
Содержание Meridian 1 Mini-Carrier Remote
Страница 2: ......
Страница 4: ...Page 4 of 150 Revision history P0914209 Standard 3 00 April 2000 ...
Страница 104: ...Page 104 of 150 Installation and configuration P0914209 Standard 3 00 April 2000 ...