Documentation Release Note
Number: MER-1002-003
No
r
tel Networks 11/4/02 17 of 26
TM
Installing cards in the Network modules
Network cards must be installed in the new Network modules as described
below. Each card must be installed and enabled or disabled as indicated.
Procedure 7
Installing cards in network modules
1
Complete “Installing and enable the 3PE cards” on page 17.
2
Complete “Installing and enabling the Peripheral Signaling (Per Sig)
cards” on page 19.
3
Complete “Disabling and inserting the FIJI cards” on page 19.
4
Complete “Disabling and inserting the Conf/TDS cards, if necessary”
on page 19.
—————————— End of Procedure ——————————
Installing and enable the 3PE cards
Three steps are required to install the 3PE cards:
Procedure 8
Installing and enabling 3PE cards
1
Verify the 3PE card settings.
The group and shelf number of each Network module is determined by
the switch settings on the 3PE card. Use the information in Table 6 on
page 18 to verify that the 3PE cards in the new Network modules have
the correct switch and jumper settings.
This group and shelf setting is displayed on the FIJI card display.
2
Install a 3PE card in slot 1 of each new Network module. Push the
latches forward to lock the card in place.
3
Attach the cables to the
inactive
3PE faceplates.
4
Faceplate
enable
each 3PE card.
—————————— End of Procedure ——————————