
334
Configuring SNMP
/cfg/sys/adm/snmp/event
followed by:
addmonitor [ <options> ]
-t <name> <OID> <value and
event>
Adds a threshold monitor and trigger as
defined in the DISMAN-EVENT-MIB.
Valid
<options>
are:
•
-c <comment>
—adds a comment
•
-f <frequency>
—the sampling
interval, in seconds. The default is 600
(10 minutes).
•
-o <OID>
—additional objects to send
in the event
•
-d <OID>
— the delta discontinuity
OID
•
-D timeTicks|timeStamp|dateAnd
Time
— the delta discontinuity type
Other parameters are:
•
name
— a unique name you assign to
the monitor, for identification
•
OID
— the object identifier (or symbolic
name) to monitor
•
value and event
—a combination
of an integer and an event condition,
where the integer represents the event
condition threshold that will trigger
notification. Valid combinations are:
<LowVal> FallingEvent
<HighVal> RisingEvent
<DeltaLowVal> DeltaFallingEve
nt
<DeltaHighVal> DeltaRisingEve
nt
Nortel Secure Network Access Switch
Using the Command Line Interface
NN47230-100
03.01
Standard
28 July 2008
Copyright © 2007, 2008 Nortel Networks
.
Содержание 425 series
Страница 525: ......