Configuring SNMP
333
The event menu includes the following options:
/cfg/sys/adm/snmp/event
followed by:
addmonitor [ <options> ] -b
<name> <OID> <op> <value>
Adds a boolean monitor and trigger as
defined in the DISMAN-EVENT-MIB.
Valid
<options>
are:
•
-c <comment>
—adds a comment
•
-f <frequency>
—the sampling
interval, in seconds. The default is 600
(10 minutes).
•
-o <OID>
—additional objects to send
in the event
•
-e <EventName>
—the name of a
notification event
•
-d <OID>
—the delta discontinuity OID
•
-D timeTicks|timeStamp|dateAnd
Time
—the delta discontinuity type
Other parameters are:
•
name
—a unique name you assign to
the monitor, for identification
•
OID
—the object identifier (or symbolic
name) to monitor
•
op
—the operator. Valid options are:
!= (not equals), == (equals), <= (less
than or equal to), >= (greater than or
equal to), < (less than), > (greater than)
•
value
—an integer indicating the value
against which the operation will be
performed