background image

12

3 AM

P

FUSE 

COMPRESSO

R

OUTDOOR

FA

N MO

TO

R

S

R

C

L2

L1

T2

T1

COMPRESSOR

CONT

AC

TO

R

24V

COM

HIGH PRESSUR

E

SWITCH

240V

LO

PRESSURE 

SWITCH

(SELECT 

MODELS 

ONL

Y)

S

R

C

5 4 3 2 1

9 8 7 6

COM

NO

NC

F

H

C

 RELA

Y

TRANSFORMER

BLUE

ORANGE

RED

BLA

CK

BLA

CK

YELLO

W

YELLO

W

YELLO

W/BL

AC

K

YELLO

W

YELLO

W/BL

AC

K

PTCR

L1

L2

GND

GR

OUNDING

SCREW

DU

AL

CAP

AC

ITION

Y1

W2

E

Y2

O

G

C

R

BLA

CK

BLA

CK

5 4 3 2 1

N G L C 

BLO

WE

R

M

OTO

R

BLA

CK

YELLO

W

1.

 Couper le courant 

av

ant de faire letretien.

2.

 Emplo

yez uniquement des conducteur

s en cuivre

.

3.

 Ne con

vient pas aux installations de plus de 150 

V a la terre

.

FIELD 

WIRIN

G

LEGEND

:

LO

VO

LT

AG

E

HIGH 

VO

LT

AG

E

WIRING DIA

GRAM

Pa

ck

ag

ed Air Conditioner - Single Phase

NO

TES:

1.

 Disconnect all po

wer bef

ore servicing.

2.

 For suppl

y connections use copper conductor

s onl

y.

3.

 Not suitable on systems that 

ex

ceed 150 

V to gr

ound.

4.

 For replacement wires use conductor

s suitable f

or 105° C.

5.

 See installation instructions f

or bl

ow

er motor airflo

w setting

s

    and terminal locations.

YELLO

W

RED

GREEN

BR

OW

N

ORANGE

RED

RED

RED

BLA

CK

BLACK

WHIT

E

ORANGE

GREEN/YELLO

W

GREY

YELLOW

RED

YELLO

W

10270890

(Replaces 711407C)

06/19

BLA

CK

BR

OW

N

SEE NO

TE 

5

Figure 10. Wiring Diagram (1.5, 2, & 2.5 Ton Models)

Wiring Diagrams

Содержание VP7RE Series

Страница 1: ...plays an important role as well Pay attention to all safety warnings and any other special notes highlighted in the manual Improper installation of the furnace or failure to follow safety warnings could result in serious injury death or property damage Theseinstructionsareprimarilyintendedtoassistqualifiedindividualsexperiencedintheproper installation of this appliance Some local codes require lic...

Страница 2: ...ate a degree or level of seriousness and should not be ignored WARNING indicates a potentially hazardous situation that if not avoided could result in personal injury or death CAUTION indicates a potentially hazardous situation that if not avoided may result in minor or moderate injury or property damage WARNING ELECTRICAL SHOCK FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly co...

Страница 3: ...rom the airflow data found in Table 3 page 11 Place appropriate wire on the appropriate motor speed tap for the required airflow GENERAL INFORMATION This packaged air conditioner is designed only for outdoor ground level installations and can be readily connected to the high static duct system of a home This unit has been tested for capacity and efficiency in accordance with AHRI Standards and wil...

Страница 4: ...r visit www NFPA org on the web Design the duct work according to methods described by the Air Conditioning Contractors of America ACCA The supply duct system including the number and type of registers will have much more effect on the performance of the system than any other factor The duct must be sufficiently large to conduct an adequate amount of air to each register See Figure 2 Duct work sho...

Страница 5: ...r greater than a 12 x 20 grille The return air grille can be placed in the wall of a closet and the air ducted into the filter box through a boxed in area at the closet floor level Figure 4 Verify the filter is readily accessible NOTE The return air box with grille and filter should not be located in heavy traffic areas like hallways or center of rooms A good spot is in a corner or under a table i...

Страница 6: ...ow safety warnings exactly could resultinseriousinjury deathorpropertydamage Improper servicing could result in dangerous operation serious injury death or property damage Beforeservicing disconnectallelectricalpower to the indoor blower When servicing controls label all wires prior to disconnecting Reconnect wires correctly Verify proper operation after servicing All electrical connections must b...

Страница 7: ...s of the NEC ANSI NFPA 70 and with applicable localcodeshavingjurisdiction Thermostatconnectionsshould Low Voltage Line Voltage be made in accordance with the instructions supplied with the thermostat and the indoor equipment Thelowvoltagewiresmustbeproperlyconnected Route24V control wires through the sealing grommet near the power entrance See Figure 7 Recommended wire gauge and wire lengths for ...

Страница 8: ...st 24 hours prior to running After unit startup the compressor must run for a minimum of 12 hours Start Up Procedure CAUTION If the unit is equipped with a crankcase heater allow 24 hours prior to continuing the start up procedures to allow for heating of the refrigerant compressor crankcase Failure to comply may result in damage and could cause premature failure of the system This warning should ...

Страница 9: ...nditions Under normal conditions the switch is closed If the liquid pressure rises above 650 psig the switch will open and de energize the unit The switch will close again when the liquid pressure decreases to 460 psig AIR CONDITIONER MAINTENANCE WARNING To prevent electrical shock personal injury or death disconnect all electrical power to the unit before performing any maintenance or service The...

Страница 10: ...n 1 12 13 1 38 3 2 3 2 5 29 Side View Figure 9 Unit Dimensions A 3 Opening for 12 Diameter Supply Duct 9 15 17 50 9 0 Opening for 14 Diameter Return Duct 10 15 5 5 B 1 3 15 Rear View 3 5 4 5 Ton MODEL NUMBER LENGTH L WIDTH W HEIGHT H A B RETURN DIAMETER IN SUPPLY DIAMETER IN 018K 49 35 22 2 35 02 2 48 12 12 024K 49 35 22 2 35 02 2 48 12 12 030K 49 35 22 2 35 02 2 48 12 12 036K 49 35 22 2 35 02 2 4...

Страница 11: ... 33 900 35 840 38 Tap T2 1313 24 1277 25 1236 26 1190 27 1153 27 1104 29 1051 30 992 32 Tap T3 1460 22 1415 22 1385 23 1335 24 1275 25 1225 26 1170 27 1120 28 Tap T4 1502 21 1466 22 1437 22 1388 23 1345 23 1305 24 1251 25 1204 26 Tap T5 1565 20 1525 21 1490 21 1450 22 1410 22 1370 23 1315 24 1270 25 042K Tap T1 1375 23 1345 23 1310 24 1275 25 1240 25 1205 26 1160 27 1120 28 Tap T2 1470 21 1435 22 ...

Страница 12: ...s en cuivre 3 Ne convient pas aux installations de plus de 150 V a la terre FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE WIRING DIAGRAM Packaged Air Conditioner Single Phase NOTES 1 Disconnect all power before servicing 2 For supply connections use copper conductors only 3 Not suitable on systems that exceed 150 V to ground 4 For replacement wires use conductors suitable for 105 C 5 See installati...

Страница 13: ... conducteurs en cuivre 3 Ne convient pas aux installations de plus de 150 V a la terre FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE WIRING DIAGRAM Packaged Air Conditioner Single Phase NOTES 1 Disconnect all power before servicing 2 For supply connections use copper conductors only 3 Not suitable on systems that exceed 150 V to ground 4 For replacement wires use conductors suitable for 105 C 5 See...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ...ty correct YES NO Has the thermostat been calibrated YES NO Is the thermostat level YES NO Is the heat anticipator setting correct If Applicable YES NO Rated Voltage __________________________________________________________________ VOLTS L1 L2 Volts ____________________________________________________________________ VOLTS INSTALLATION ADDRESS CITY__________________________________________ STATE_...

Отзывы: