29
CC
H
IF
EQUIPPED
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
240V
208V
24
V
CO
M
1
2
3
1
2
3
A1
W2
Y2
R
C
Y1
G
W1
5432
1
5432
1
VA
RIABL
E
SPEE
D
BL
OWER
MO
TO
R
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
R
S
C
R
S
C
C
HF
TO
208/230
VA
C
POWER SUPPL
Y
FLAME SENSOR
HPS
INDUCER
MO
TO
R
IGNI
TO
R
LO
W
PRESSUR
E
SWIT
CH
HIGH
PRESSUR
E
SWI
TC
H
L2
L1
T1
T2
P6 16-PIN
2
1
3
6
5
4
7
8
9
12
11
10
W1
W2
C
R
G
Y
Y2
0
DEHUM
NEUTRALS
HU
M
LINE
XMFR
CO
NT
EA
C
CO
OL
PA
RK1
PARK2
HI-HEA
T
LO
-HEA
T
P2
1
5
LPS
TRANSFORME
R
HIGH
TEMP
LIMIT
OUTDOOR FAN MO
TO
R
DU
AL
CA
PA
CI
TO
R
EC
ONOMIZE
R
PL
UG
EC
ONOMIZE
R
PL
UG
ECONOMIZER JUMPER
HARNESS ASSY. 8-
WIRE
CO
MFOR
T
ALERT
Y2
Y
C
R
S
L
R
C
DC
SOL
(C
FM
)
YE
L
GREEN HI/L
O
DEHUMIDIF
Y
IGNITION / BL
OWE
R
CONTROL BO
ARD
(HIGH HE
AT
DEMAND
)
GREE
N
(S
TA
TUS)
RE
D
AU
TO
HE
AT
ST
AG
E
10 5 NONE
COOL A B C
D
HE
AT
A B C
D
ADJUS
T
NORM
(+)
(-)
TEST
5A FUSE
HI
LO
PRIMAR
Y
GAS
VA
LV
E C
2
1
3
FLAME ROLL
-O
UT
AIR SENSOR
TO
DISCHARGE
BLA
CK
WHITE
RE
D
RED
RED
R
OS
SE
RP
M
OC
RE
D
YELL
OW
YELL
OW
ORANGE
BLUE
YELLOW
BLACK
GRAY
GREEN
YELLOW
CO
NTROL
WIRING LEADS
Ref
er to Installation Instru
ct
ions f
or
Connec
tion to Indoor
Thermostat
Note: See Installation Instruc
tions
WHITE
WHITE
GREEN
YELL
OW
VIOLE
T
ORANGE
BLUE
BL
UE
YELL
OW
BROWN
GREEN
BLACK
RE
D
YELLOW
BL
UE
WHITE
RED
RE
D
BLACK
BLA
CK
BLA
CK
YELL
OW
YELL
OW
YELL
OW
BLACK
YELLOW
BL
UE
BLUE
GREEN
GREEN
BLACK
RED
BROWN
BROW
N
RE
D
BLA
CK
RE
D
WHITE
BROWN
BROWN
BLA
CK
WHITE
BLA
CK
RE
D
GR
AY
BLA
CK
YELL
OW
BL
UE
GREEN
BLA
CK
SEE NO
TE
6
H
W/
KB
E
G
N
AR
O
KB
/E
Y
DE
R
YELLOW
BLACK
YELL
OW
BL
UE
BROW
N
BROW
N
TO
WHITE ROOGER
S
THERMOST
AT
"L
" ON
LY
WHITE
WHITE
208/230
Volt Single Phas
e
Pack
aged
Tw
o Stage Heat/T
wo Stage Elec
tric Air Conditione
r
60H
z
WIRING DIA
GRAM
NO
TES:
1. Disconnec
t power be
fo
re ser
vicing
.
2. F
or supply connec
tions use copper conduc
tors only
.
3. Not suitable on systems that ex
ceed 150V to ground
.
1. Couper le courant avant de faire letretien. 2. Employez uniquement des condu
ct
eurs en cuivre
.
3. Ne co
nv
ient pas aux installations de plus de 150
V
a la terr
e.
4. If an
y of the original wire as supplied with the furnace must be replaced, it must
be replaced with wiring material having a temperature rating of at least 105°C. 5. F
or supply wire ampacities and overcurrent protec
tion, see unit rating plate
.
6.F
or 208V operation,inducer motor low speed resistor must be bypassed.
Removed RED wire from resistor block and conne
ct
to piggyback terminal
on opposite side
.
FIELD
WIRIN
G
LEGEND:
LO
W
VO
LT
AG
E
HIGH
VO
LT
AG
E
SY
STEM ST
AT
US - IGNITION
Po
wer On (Normal Operation)
High Limit Ci
rcuit Open
Pr
essure Switch Open with Inducer On
Fa
iled Ignition (5 attemps) - Control in 1 Hour
Lo
ckou
t
208-230
Volt P
olarity Issu
e
Ex
cess High limit trips (5) within one call f
or hea
t
Ex
cess pressure switch
cy
cles (5) within one call f
or hea
t
Not Used
LED ST
AT
US (RED
)
ON 1
Fl
as
h
2
Fl
ashes
3
Fl
ashes
4
Fl
ashes
5
Fl
ashes
6
Fl
ashes
7
Fl
ashes
8
Fl
ashes
9
Fl
ashes
10
Fl
ashes
SY
STEM ST
AT
US - 2nd ST
AG
E HE
AT
DEMAND
No demand f
or 2nd stage hea
t
2nd stage heat demand (Normal operation) 2nd stage heat demand, high pressure switch not closed
LED ST
AT
US
(G
REEN
)
OFF ON Fl
ashing
SY
STEM ST
AT
US - CF
M
NO
T USED
LED ST
AT
US
(Y
EL
LO
W)
OFF
SY
STEM ST
AT
US - HI/L
O DEHUMIDIFY
(C
ooling Mode only
)
Fa
ct
or
y jumper wire
“R
” to
“DEHUM
” in place or
“C
lose on
Fa
ll”
humidistat (L
ow humidit
y) - Closed
Humidistat open (High Humidity)
Lo
w Speed Blower cal
l
LED ST
AT
US
(G
REEN
)
ON OFF
10065150
11/20
GAS
VA
LV
E
624787
Figure 14. Two Stage Cool, Two Stage Heat with Optional Comfort Alert
Содержание R6GF Series
Страница 35: ...35...