background image

TABLE OF CONTENTS

IMPORTANT SAFETY INFORMATION .........................2
GENERAL INFORMATION ............................................2

Clearances to Combustibles ...........................................3

Wiring Diagrams ..............................................................3

Clearances ......................................................................3

ELECTRICAL SUPPLY ..................................................3

Installation Preparations .................................................3

Terminal Blocks ...............................................................3

Circuit Options .................................................................3

Single Branch Circuit Electrical Connection ..................3

Multiple Branch Circuit Electrical Connection ................3

Circuit Breakers ...............................................................3

Breaker Removal ...........................................................4

HEAT KIT INSTALLATION .............................................4
AIRFLOW .......................................................................6
FIGURES AND TABLES ................................................6

Table 3. Heater Kit Model Cross Reference ...................6

Electrical Data .................................................................7

Table 4. MCA/MOP Data (Single Circuit) .......................7

Table 5. MCA/MOP Data (Multiple Circuit).....................8

Electrical Diagrams .........................................................9

Figure 13. Single and Dual Power Supply Connections 9

Figure 14. Wiring Diagram for 9 kW, 240V, 3-Phase ......10

Figure 15. Wiring Diagram for 9 kW, 480V, 3-Phase ......11

Figure 16. Wiring Diagram for 18 kW, 240V, 3-Phase ....13

Figure 17. Wiring Diagram for 18 kW, 480V, 3-Phase ....14

Figure 18. Wiring Diagram for 30 and 35 kW, 

240V, 3-Phase ............................................................16

Figure 19. Wiring Diagram for 30 and 35 kW, 

480V, 3-Phase ............................................................17

IMPORTANT SAFETY INFORMATION

INSTALLER: Please read all instructions before servicing 

this equipment. Pay attention to all safety warnings and 

any other special notes highlighted in the manual. Safety 

markings are used frequently throughout this manual to 

designate a degree or level of seriousness and should not 

be ignored. 

WARNING indicates a potentially hazardous 

situation that if not avoided, could result in personal injury or 

death. 

CAUTION indicates a potentially hazardous situation 

that if not avoided, may result in minor or moderate injury or 

property damage.

 WARNING:

RISK OF ELECTRICAL SHOCK

Shut off all electrical power to the unit before 

performing any maintenance or service on the system. 

Failure to follow this warning can cause serious injury, 

fire, electrical shock, or death.

•  The installer performing this work assumes all responsibility 

when installing this kit. These instructions are primarily 

intended to assist qualified individuals experienced in the 

proper installation of these components. Some local codes 

may require licensed installation/service personnel for this 

type of equipment. Safety should always be the deciding 

factor when installing this product and using common sense 

plays an important role as well. Improper installation of 

the components or failure to follow safety warnings could 

result in serious injury, death, or property damage.

•  Unless noted otherwise in these instructions, only factory 

authorized parts or accessory kits may be used with this 

product. Improper installation, service, adjustment, or 

maintenance may cause fire, electrical shock or other 

hazardous conditions which may result in personal injury 

or property damage.

•  Please read all instructions carefully before starting the 

installation. If a problem occurs, check the instructions 

and follow recommendations given.

• The information shown in these instructions must be 

followed during the installation of this kit. Unqualified 

individuals should not attempt to interpret these instructions 

or install this equipment. If you do not possess mechanical 

skills or tools, call your local dealer for assistance.

•  Use caution when handling the appliance or removing 

components. Personal injury can occur from sharp metal 

edges present in all sheet metal constructed equipment.

GENERAL INFORMATION

H9HK heater kits are approved for use in P7TQ packaged air 

conditioners when applied and installed according to these 

instructions. Use the model identification code in 

Figure 1

 

and 

Table 1

 for approved H9HK heat kit applications in air 

conditioner systems. Refer to the National Electric Code 

(ANSI/NFPA 70) or in Canada the Canadian Electric Code 

Part 1 (CSA C.22.1) and applicable local codes for overcurrent 

H

9

HK

009

-

H

 

1

Heater

Heater Kit

 

9 = (P,Q)7TQ

Electric Heater

009 - 9KW

018 - 18 KW

030 - 30 KW

035 - 35KW

No. of Breakers

Electric Code
N = 575-3-60
Q = 208/240-3-60
S = 480-3-60

Stages

Figure 1. Heater Kit Identification Code

2

CP-H9HK (05-20) 1012566-B

Содержание 1011669

Страница 1: ...with these instructions and with all applicable national and local codes and standards Please read all instructions carefully before starting the installation Return these instructions to the customer...

Страница 2: ...ons are primarily intended to assist qualified individuals experienced in the properinstallationofthesecomponents Somelocalcodes may require licensed installation service personnel for this type of eq...

Страница 3: ...and DO NOT serve as a unit disconnect The circuit breakers DO NOT provide over current protection of the supply wiring Whether or not circuit breakers are used in the units protection and disconnect...

Страница 4: ...supply grille 1 Remove Compressor Access panel See Figure 2 foam wire guards for later use See 4 Install the DIN rail mounting bracket inside of the unit and tightly secure it with two screws See NOT...

Страница 5: ...m flange of the element mounting plate to the bottom pan and then one in the rear of the element assembly support bracket as shown in and 11 Route all wiring out the two wire passage holes and foam wi...

Страница 6: ...0Q 21 1011675 2 Figure 18 210 F 35 H9HK035Q 21 1011678 2 Figure 18 210 F 6 7 5 10 and 12 5 ton 460V 3PH P7TQ 072 090 120 150 D 9 H9HK009S 01 1011670 NONE Figure 15 155 F 18 H9HK018S 01 1011673 NONE Fi...

Страница 7: ...49 4 58 5 30 35 50 60 UNIT EQUIPPED WITH 3 HP 2 SPEED MOTOR HEATER KIT 3 HP 2 SPEED MOTOR HEATER KIT POWER EXHAUST COOLING TONNAGE UNIT VOLTAGE MCA MOP MCA MOP 9 KW 18 KW 30 KW 35 KW 9 KW 18 KW 30 KW...

Страница 8: ...7 40 31 7 40 31 7 40 31 7 40 14 9 15 27 1 30 43 3 45 52 3 60 HIGH STATIC DRIVE OPTIONAL 3 HP ECM MOTOR 6 208 240 33 7 50 33 7 50 33 7 50 33 7 50 23 5 27 1 30 30 45 4 52 3 50 60 75 0 86 6 80 90 90 7 1...

Страница 9: ...POWER SUPPLY L1 L2 L3 To Cooling Circuit Power Supply Disconnect Main Control Panel 3 Pole Terminal Block To Cooling Components and Control L1 L2 L3 L1 L2 L3 Electric Heat 3 Pole Terminal Block Elect...

Страница 10: ...BE REPLACED WITH WIRING MATERIAL OF THE 1 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE UNIT MUST BE NOTES 2 USE COOPER CONDUCTORS WITH A MINIMUM TEMPERATURE RATING OF 60 C FOR SUPPLY CONNECTIONS 1...

Страница 11: ...T BE REPLACED WITH WIRING MATERIAL OF THE 1 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE UNIT MUST BE NOTES 2 USE COOPER CONDUCTORS WITH A MINIMUM TEMPERATURE RATING OF 60 C FOR SUPPLY CONNECTIONS...

Страница 12: ...OF THE ORIGINAL WIRE AS SUPPLIED WITH THE UNIT MUST BE NOTES 2 USE COOPER CONDUCTORS WITH A MINIMUM TEMPERATURE RATING OF 60 C FOR SUPPLY CONNECTIONS 1012105A Replaces 10121050 05 17 18 kW 1 Stage 20...

Страница 13: ...RING MATERIAL OF THE 1 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE UNIT MUST BE NOTES 2 USE COOPER CONDUCTORS WITH A MINIMUM TEMPERATURE RATING OF 60 C FOR SUPPLY CONNECTIONS 1012106A Replaces 10...

Страница 14: ...HE ORIGINAL WIRE AS SUPPLIED WITH THE UNIT MUST BE NOTES 2 USE COOPER CONDUCTORS WITH A MINIMUM TEMPERATURE RATING OF 60 C FOR SUPPLY CONNECTIONS 1012108A Replaces 10121080 05 17 30 35 kW 1 Stage 208...

Страница 15: ...THE ORIGINAL WIRE AS SUPPLIED WITH THE UNIT MUST BE NOTES 2 USE COOPER CONDUCTORS WITH A MINIMUM TEMPERATURE RATING OF 60 C FOR SUPPLY CONNECTIONS 1012109A Replaces 10121090 05 17 30 35 kW 1 Stage 48...

Страница 16: ...HESE INSTALLATION INSTRUCTIONS WITH THE HOMEOWNER Specifications and illustrations subject to change without notice or incurring obligations 2020 Nortek Global HVAC LLC O Fallon MO All rights reserved...

Отзывы: