EasyGrid User Guide
90
IMPORTANT
When installing sensors in the windings, it is recommended not to take up more than 10% of the coil
surface.
In general, it is preferable to install sensors as far along the manufacturing process as possible in order to
minimize handling. Consequently, if only a single layer is specified for the winding, installation of the
sensors can be done after sizing. If more than one layer is planned and the sensors are to be located on
the inner layer, they should be installed when the first layer has been completed. In both cases, the coil
should be manufactured as if no sensors were to be installed, i.e. all radial spacers should be put in
place. It is easier and more efficient simply to remove normal spacers and replace them with spacers to
which sensors have been attached when it is time to do the installation.
11.2
Handling Optical Cable
The core of any fiber optic cable is glass. For this reason it should be handled with care and should not
be viewed like a standard conventional electrical cable. If it is pinched, twisted, over bent or crushed,
the glass core will break and the light attenuation will occur at this point.
Fiber optic sensors are pretty robust but…
Avoid sharp bend
Avoid kinking, twisting
Avoid putting any tension on the cable
Avoid dropping connector on hard surfaces
Содержание EasyGrid V1
Страница 1: ...EasyGrid User Guide i Nortech EasyGrid User Guide MAN 00084 R 10 0 ...
Страница 24: ...EasyGrid User Guide 19 6 Hardware Configuration 6 1 Dimensions ...
Страница 97: ...EasyGrid User Guide 92 11 3 Assembly Diagram ...
Страница 99: ...EasyGrid User Guide 94 11 4 1 2 Pre Drilling 11 4 1 3 Using the Knockout Punch ...
Страница 100: ...EasyGrid User Guide 95 11 4 1 4 Cutting the Cable Slot 11 4 1 5 Inserting the Easy Disk ...