NANOQUEST USER GUIDE
Issue 02
5-4
Typical Wiring of an external alarm device using an intermediate circuit:
Configuring the Alarm Output
5.4.2.
It is possible to configure the alarm output to either latch for the duration of the alarm condition or to
give a single one-second pulse when the alarm first occurs. The choice of output depends upon the
requirement of the external device that you intend to connect the output to. The factory setting for the
Alarm output is to latch. You will only need to change this setting if you need a pulsed Alarm output or
if the unit has been used previously and the current settings are not known.
The procedure for setting the Alarm Output mode is as follows:
Description
Action
Indication
Final State
1) Enter ‘Configure Alarm Output’
mode by presenting the Master
five times.
The
LED blinks green and the
unit beeps twice to indicate
programming mode has been
entered successfully. The LED
then blinks green once and the
unit beeps once on the second
and subsequent presentations.
The LED repeats a sequence
of 5 red flashes followed by a
pause to indicate Mode 5.
x5
First presentation:
x1
x2
Second and subsequent
presentations:
x1
x1
x5
Followed by a pause.
Sequence is repeated.
2) Present a valid User or
Auxiliary card.
The LED blinks green once
and then repeat a sequence
of single red flashes
followed
by a short pause to indicate
that ‘Latch Mode’ has been
selected.
x1
x1
x1 (Latch)
Followed by a pause.
Sequence is repeated.
Red
Black
9 to
16V DC
+ve
-ve
Blue
Load
Intermediate
Circuit
(e.g. relay)
Power Supply