![Nortec UL10 Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/nortec/ul10/ul10_operation-manual_1705753065.webp)
CHARGER / DISCAHRGER UL10
OPERATION MAUNAL
64
©
NorTec Electronics 2014
7.27 Program 516. Direct current charging – Pb battery vented commercial
Stage
name
Maximum
duration
Program
number
516
Operation
number
5
Operation
type
Direct
current
charging
Battery
type
Lead
acid
Manufacturing
process
Liquid
electrolyte
Access
to
valves
open
Battery
type
16
Minimum
battery
capacity
10 Ah
Maximum
battery
capacity
400 Ah
Minimum
battery
voltage
2 V
Maximum
battery
voltage
30 V
Maximum number of batteries
15
Stage 1 (
S1
)
I-Charge Current
free selection
Stage 1 (
S1
)
I-Charge Umax
=
V/battery
2.4
Stage 1 (
S1
)
I-Charge time
free selection
Содержание UL10