7.25 Program 510. Direct current charging – air-tight aircraft lead acid bat-
tery
Stage
name
Maximum
duration
Program
number
510
Operation
number
5
Operation
type
Direct
current
charging
Battery
type
Lead
acid
Manufacturing
process
Gel
/
absorbed
electrolyte
Access
to
valves
Unavailable
Battery
type
10
Minimum
battery
capacity
2 Ah
Maximum
battery
capacity
200 Ah
Minimum
battery
voltage
2
Maximum
battery
voltage
30
Maximum number of batteries
15
Stage 1 (
S1
)
I-Charge I
free selection
Stage 1 (
S1
)
I-Charge Umax
=
V/battery
2.4
Stage 1 (
S1
)
I-Charge time
free selection