86
Chapter 18
Technical specifications
87
Norsonic Nor118
User Guide
by means of the and keys. Do the same to
deactivate. Random response correction activated is
indicated by an
R
in the lower line of the display.
Windscreen
e instrument may be used with windscreen Nor1451.
e windscreen correction has to be switched on to obtain
the stated specifications. e nominal correction for the
windscreen correction network is shown in the figure
below.
Activating windscreen correction
• Press > 1 (Instr.) > 6 (Correct.) to gain access to
the Corrections menu. Navigate in the menu as usual
and activate the correction parameter Windscr by
means of the and keys. Do the same to deac-
tivate. Windscreen correction activated is indicated by
a
W
in the lower line of the display.
High levels
As an option, the instrument may measure levels 10 dB
higher than stated as the standard range. e extended
measurement range is obtained by reducing the sensitiv-
ity of the microphone through the application of a lower
polarisation voltage. When this option is selected, the
Содержание nor118