Technical specifications
87
Norsonic Nor118
User Guide
Measurement range for C-weighted peak levels
Frequency 31.5 Hz
1 kHz
4 kHz
8 kHz 12.5 kHz
Upper level
137 dB 140 dB 139 dB 137 dB 134 dB
Lower level
45 dB
45 dB
45 dB
45 dB
45 dB
Ref level test
114 dB 114 dB
114 dB 114 dB
114 dB
Power supply
Battery:
4 cells, , -sized, batteries are
recommended (e.g. ). -sized NiCd
or NiMH rechargeable batteries may be used, but must be
charged outside the instrument. Battery voltage and time
on battery since last change of batteries are indicated.
Typical battery life time
( )
:
8 hours.
External
DC
:
11 – 15 volt. Power consumption approxi-
mately 1.4 watt dependent on selected modes of operation.
External source should have source-impedance less
than 1 ohm and be able to supply at least 300 mA. e
mains adaptor Nor340 is recommended for use with the
instrument.
If the external supply falls below 9 V, the instrument
will use the internal batteries if available. If the instru-
ment has switched off due to loss of power or insufficient
supply voltage, the instrument will automatically switch
on and resume normal operation after reapplying the
external supply.
Socket for external
DC
:
1.3 mm plug, negative voltage
on centre-terminal.
e instrument will automatically switch off if the battery
or external voltage is too low for operation within the
stated specifications. e maximum battery voltage for
conformance testing is 4 × 1.6 V = 6.4 V.
e instrument has a calendar clock with a typical
lifetime of more than 10 years. Contact your Norsonic
service department for change of this component. After
replacement the instrument need factory calibration and
to re-install the options.
Display
e display is a monochrome, transreflective graphi-
cal display with 160×240 pixels (W×H) with automatic
temperature compensation for contrast and viewing angle.
Pressing the key illuminates the display. e light
switches off automatically 2 minutes after the last opera-
tion of any key.
e bar graph display covers 80 dB, which may be
scrolled in 10 dB steps to cover the total range.
Keyboard
e keyboard is of foil type with acoustic feedback when
the keys are depressed. Keys used during a measurement
or for initiating a measurement remain silent.
Adjustment of indicated levels
Random response.
e instrument is equipped with a
microphone with flat free-field response and satisfies the
class 1 requirements in - to free-field response.
By selecting the random response correction network
included, the instrument will satisfy the class 1 require-
ments in - to random response as well as
.- . e nominal correction to obtain flat
random response is shown in the figure below.
Activating random response correction:
• Press > 1 (Instr.) > 6 (Correct.) to gain access
to the Corrections menu. Navigate in the menu as
usual and activate the correction parameter Random