![Norland Elite 437A150 Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/norland/elite-437a150/elite-437a150_operators-manual_1705413103.webp)
Operator's Guide
437D140 Rev. I
Installation and Setup
3-47
Tools Command
To view the Tools commands, click on Tools in the Database Navigator window.
Quick Descriptions: “Tools” drop-down list
Initialize Scanner: Select this feature if the message “Scanner Not Present” appears at the bottom of the Data-
base Navigator window and the scanner is powered on. The Scanner will re-initialize.
Service Tools: contains the Find Origin, Table Limits, and Begin Initial Calibration commands. See "Find Ori-
gin" on the next page, "Table Limits" on page 3-49, or "Begin Initial Calibration" on page 3-50 for details.
File Tools: for detailed patient and scan information and system diagnostics files.
Calibration Details: for system diagnostics. Various calibration files can be viewed.
Send To: This (cascading) menu option provides a way for operators to copy a Scan from the Bone Dens-
itometer software to any of the drives (e.g., C:\, floppy, network share), or a folder. From the Stamp View, the
operator should select one or more scans, select Tools > Send To, and select the drive of choice in the sub-
menu.
Update Report Scan Type Values: This command will update the scan types on all previously generated
reports in all databases. The command will disappear from the menu once it has been executed once.
DICOM Interface: This command will launch the DICOM Interface. Refer to Chapter 13, DICOM Interface
for more information. The option will only be available if enabled by an OAC.
Mail: This tool enables the operator to e-mail patient data in a FolderMail file to a colleague. It also displays the
E-mail address book. Refer to "FolderMAIL" on page 11-9 for information.
Report: This selection enables the operator to select a report template, generate a new report, and edit existing
Reports (
Complete Report
command). Full instructions on how to generate and print a report is included at the
end of each type of scan chapter (for example "Generate and Print a Report" on page 7-24 for AP Spine scans).
Audio Dictation: An Audio Dictation enables a person to record anything, including a report dictation pertaining
to the selected scan that can be written up later. Refer to "Adding Audio to a Patient Record" on page 11-2 for
info.
Log Files: This pull-down provides a secondary menu allowing the administrator to access the following log
files:
Scanner: errors.log
Calibration: calib.trc
Import DB: dbimport.log
Runtime: client.log
Содержание Elite 437A150
Страница 1: ...DXA Bone Densitometer Operator s Guide Elite Model 437A150 Operator s Guide 437D140 Rev I...
Страница 22: ...This page intentionally left blank Operator s Guide 437D140 Rev I 1 8...
Страница 41: ...Operator s Guide 437D140 Rev I General Information 2 19 Figure 2 6 Page 2 of the Bone Exam Report...
Страница 45: ...Operator s Guide 437D140 Rev I General Information 2 23 Figure 2 10 Page 2 of the Patient Letter...
Страница 47: ...Operator s Guide 437D140 Rev I General Information 2 25 Figure 2 12 Page 2 of the Referral Letter...
Страница 49: ...Operator s Guide 437D140 Rev I General Information 2 27 Figure 2 14 Page 2 of the Ten Year Fracture Risk Report...
Страница 56: ...This page intentionally left blank Operator s Guide 437D140 Rev I 2 34...
Страница 66: ...11 Click Operator s Guide 437D140 Rev I 3 10 Installation and Setup...
Страница 108: ...This page intentionally left blank Operator s Guide 437D140 Rev I 3 52...
Страница 124: ...Sample Printed QA Results Report Operator s Guide 437D140 Rev I 4 16 Basic Operation...
Страница 137: ...Operator s Guide 437D140 Rev I Basic Operation 4 29...
Страница 165: ...Operator s Guide 437D140 Rev I Scanning Whole Body 5 23 Figure 5 6 Page 2 of the Bone Exam Report...
Страница 166: ...This page intentionally left blank Operator s Guide 437D140 Rev I 5 24...
Страница 176: ...Figure 6 2 Page 2 of the Bone Exam Report Operator s Guide 437D140 Rev I 6 10 Soft Tissue Composition...
Страница 178: ...Figure 6 4 Page 2 of the Body Composition Report Operator s Guide 437D140 Rev I 6 12 Soft Tissue Composition...
Страница 198: ...Operator s Guide 437D140 Rev I 7 20 Scanning AP Spine...
Страница 205: ...Operator s Guide 437D140 Rev I Scanning AP Spine 7 27 Figure 7 5 Page 2 of the Bone Exam Report...
Страница 206: ...This page intentionally left blank Operator s Guide 437D140 Rev I 7 28...
Страница 238: ...Figure 8 6 Page 2 of the Bone Exam Report Operator s Guide 437D140 Rev I 8 32 Scanning Hip...
Страница 289: ...Operator s Guide 437D140 Rev I Scanning Lateral Spine 10 29 Figure 10 6 Page 2 of the Bone Exam Report...
Страница 290: ...This page intentionally left blank Operator s Guide 437D140 Rev I 10 30...
Страница 301: ...Operator s Guide 437D140 Rev I Additional Techniques 11 11 6 The dialog box closes and the file is sent...
Страница 326: ...Operator s Guide 437D140 Rev I 11 36 Additional Techniques...
Страница 378: ...Figure 12 2 Page 1 of the Ten Year Fracture Risk Report Operator s Guide 437D140 Rev I 12 10 Ten Year Fracture Risk...
Страница 412: ...This page intentionally left blank Operator s Guide 437D140 Rev I 14 16...
Страница 428: ...This page intentionally left blank Operator s Guide 437D140 Rev I 16 10...
Страница 446: ...Label Locations continued Operator s Guide 437D140 Rev I 17 18 Technical Reference...
Страница 448: ...Scanner Labels continued Operator s Guide 437D140 Rev I 17 20 Technical Reference...
Страница 449: ...Operator s Guide 437D140 Rev I Technical Reference 17 21 Scanner Labels continued...
Страница 457: ...Operator s Guide 437D140 Rev I Reference Data Sets 18 7 Excerpt from Calcified Tissue International...
Страница 458: ...Excerpt from the Journal of Bone and Mineral Research Operator s Guide 437D140 Rev I 18 8 Reference Data Sets...
Страница 459: ...Operator s Guide 437D140 Rev I Reference Data Sets 18 9...
Страница 466: ...Operator s Guide 437D140 Rev I This page intentionally left blank...
Страница 484: ...Operator s Guide 437D140 Rev I This page intentionally left blank...