Table 5. Continued

*TA / *TK FURNACES with FIXED SPEED BLOWERS

Model Number

&

Heating Input

(Btuh)

Motor Switch Settings

(0 = OFF, 1 = ON)

External Static Pressure (in.W.C.)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

1/5

2/6

3/7

4/8

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM Rise

*TA / TK - 100C - 35C1

(100,000)

0

0

0

0

1,125

66

1,040

71

960

77

  

1

0

0

0

1,205

61

1,120

66

1,040

71

960

77

0

1

0

0

1,305

57

1,225

60

1,150

64

1,070

69

995

74

915

81

    

1

1

0

0

1,430

52

1,350

55

1,270

58

1,190

62

1,110

67

1,030

72

950

78

865

86

0

0

1

0

1,525

49

1,450

51

1,375

54

1,300

57

1,225

60

1,150

64

1,075

69

1,000

74

1

0

1

0

1,620

46

1,540

48

1,465

51

1,390

53

1,315

56

1,240

60

1,165

64

1,090

68

0

1

1

0

1,695

44

1,620

46

1,545

48

1,465

51

1,390

53

1,315

56

1,235

60

1,160

64

1

1

1

0

1,770

42

1,700

44

1,630

45

1,555

48

1,485

50

1,410

53

1,340

55

1,265

59

0

0

0

1

1,875

40

1,805

41

1,730

43

1,655

45

1,580

47

1,510

49

1,435

52

1,340

55

1

0

0

1

1,905

39

1,840

40

1,775

42

1,710

43

1,640

45

1,575

47

1,510

49

1,445

51

0

1

0

1

1,980

37

1,910

39

1,845

40

1,780

42

1,715

43

1,650

45

1,580

47

1,515

49

1

1

0

1

2,025

37

1,960

38

1,895

39

1,830

40

1,765

42

1,700

44

1,635

45

1,570

47

0

0

1

1

2,085

36

2,025

37

1,960

38

1,900

39

1,840

40

1,775

42

1,715

43

1,655

45

1

0

1

1

2,135

35

2,070

36

2,010

37

1,945

38

1,880

39

1,815

41

1,750

42

1,685

44

0

1

1

1

2,200

34

2,145

35

2,090

35

2,035

36

1,980

37

1,925

38

1,870

40

1,820

41

1

1

1

1

2,280

32

2,225

27

2,170

34

2,115

35

2,065

22

2,010

37

1,955

38

1,900

39

*TA / TK - 120C - 35C1

(120,000)

0

0

0

0

1,125

79

1,040

    

1

0

0

0

1,205

74

1,120

79

1,040

85

0

1

0

0

1,305

68

1,225

73

1,150

77

1,070

83

  

1

1

0

0

1,430

62

1,350

66

1,270

70

1,190

75

1,110

80

1,030

86

  

0

0

1

0

1,525

58

1,450

61

1,375

65

1,300

68

1,225

73

1,150

77

1,075

83

1,000

89

1

0

1

0

1,620

55

1,540

58

1,465

61

1,390

64

1,315

68

1,240

72

1,165

76

1,090

82

0

1

1

0

1,695

52

1,620

55

1,545

58

1,465

61

1,390

64

1,315

68

1,235

72

1,160

77

1

1

1

0

1,770

50

1,700

52

1,630

55

1,555

57

1,485

60

1,410

63

1,340

66

1,265

70

0

0

0

1

1,875

47

1,805

49

1,730

51

1,655

54

1,580

56

1,510

59

1,435

62

1,340

66

1

0

0

1

1,905

47

1,840

48

1,775

50

1,710

52

1,640

54

1,575

56

1,510

59

1,445

62

0

1

0

1

1,980

45

1,910

47

1,845

48

1,780

50

1,715

52

1,650

54

1,580

56

1,515

59

1

1

0

1

2,025

44

1,960

45

1,895

47

1,830

49

1,765

50

1,700

52

1,635

54

1,570

57

0

0

1

1

2,085

43

2,025

44

1,960

45

1,900

47

1,840

48

1,775

50

1,715

52

1,655

54

1

0

1

1

2,135

42

2,070

43

2,010

44

1,945

46

1,880

47

1,815

49

1,750

51

1,685

53

0

1

1

1

2,200

40

2,145

41

2,090

43

2,035

44

1,980

45

1,925

46

1,870

48

1,820

49

1

1

1

1

2,280

39

2,225

40

2,170

41

2,115

42

2,065

43

2,010

44

1,955

45

1,900

47

*TA / TK - 140C - 45D1

(140,000)

0

0

0

0

1,395

74

1,350

77

1,305

79

1,260

82

1,210

86

1,165

89

1

0

0

0

1,465

71

1,420

73

1,375

75

1,330

78

1,290

80

1,245

83

1,200

86

  

0

1

0

0

1,555

67

1,510

69

1,470

71

1,425

73

1,380

75

1,340

77

1,295

80

1,250

83

1

1

0

0

1,625

64

1,585

65

1,540

67

1,500

69

1,460

71

1,415

73

1,375

75

1,335

78

0

0

1

0

1,690

61

1,650

63

1,610

64

1,570

66

1,530

68

1,485

70

1,445

72

1,405

74

1

0

1

0

1,760

59

1,715

60

1,670

62

1,625

64

1,575

66

1,530

68

1,485

70

1,440

72

0

1

1

0

1,835

57

1,790

58

1,745

59

1,695

61

1,650

63

1,605

65

1,555

67

1,510

69

1

1

1

0

1,885

55

1,840

56

1,790

58

1,745

59

1,700

61

1,655

63

1,610

64

1,565

66

0

0

0

1

1,945

53

1,900

55

1,850

56

1,805

57

1,760

59

1,710

61

1,665

62

1,620

64

1

0

0

1

1,950

53

1,905

54

1,860

56

1,820

57

1,775

58

1,735

60

1,690

61

1,650

63

0

1

0

1

2,075

50

2,030

51

1,990

52

1,945

53

1,900

55

1,855

56

1,810

57

1,770

59

1

1

0

1

2,125

49

2,085

50

2,040

51

2,000

52

1,955

53

1,910

54

1,870

55

1,825

57

0

0

1

1

2,170

48

2,130

49

2,090

50

2,045

51

2,005

52

1,965

53

1,925

54

1,880

55

1

0

1

1

2,215

47

2,180

48

2,140

48

2,105

49

2,070

50

2,035

51

2,000

52

1,965

53

0

1

1

1

2,225

47

2,165

48

2,100

49

2,040

51

1

1

1

1

2,170

48

2,120

49

2,065

50

NOTES:

1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.
2. Two openings are recommended for airfl ows above 1,600 CFM if the fi lter(s) is (are) adjacent to the furnace.
3. Data is shown without fi lter.
4. Temperature rises in the table are approximate. Actual temperature rises may vary.
5. Temperature rises that are shaded in grey are for reference only. These conditions are not recommended.
6. When in low stage, the circulating airfl ow is 70% of the tables high value. (2-stage furnaces only)

Содержание *TA UPFLOW / HORIZONTAL

Страница 1: ...llow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING RISQUE D INCENDIE OU D EXPLOSION Le non respect des avertissements de s curit pourrait entra...

Страница 2: ...Inlet 12 Downflow Installation 12 Installation on a Concrete Slab 13 Horizontal Installation 13 Pressure Switches 14 Bottom Panel Removal 14 Alternate Bottom Panel Removal 14 GAS SUPPLY PIPING 15 Lea...

Страница 3: ...installation service and operation of this furnace Failure to follow safety recommendations could result in possible damage to the equipment serious personal injury or death This furnace must be insta...

Страница 4: ...y This furnace is designed to operate with return air temperatures in ranges normally found in occupied residences including setbacks Minimum continuous return temperature must not be below 60 F 15 C...

Страница 5: ...Canadian Electrical Code CSA C22 1 Gas Piping and Gas Pipe Pressure Testing US NFGC and National Plumbing Codes CANADA NSCNGPIC General Installation US Current edition of the NFGC and the NFPA 90B Fo...

Страница 6: ...n vacuent correctement tel que prescrit ci dessus rouvrir les portes et les fen tres et remettre les ventilateurs d vacuation les registres de foyers et tout autre appareil fonctionnant au gaz leur ta...

Страница 7: ...on air from that space Furnace closets small equipment rooms and garages are confined spaces Furnaces installed in a confined space which supply heated air to areas outside the space must draw return...

Страница 8: ...must be at least 1 sq in per 4 000 Btuh of total input rating Outlet air duct must be at least 1 sq in per 4 000 Btuh of total input rating Must extend above attic insulation Water Heater Furnace Vent...

Страница 9: ...pliances The vent system dimensions and material must conform to the NFGC or local Codes Generally this means using Type B vent pipe or a lined masonry chimney When consulting the vent sizing tables i...

Страница 10: ...vent system should also be checked to make sure it remains in compliance with the National Fuel Gas Code If it isn t the vent system must be brought into compliance before installing the furnace Horiz...

Страница 11: ...urnace is equal to the return air supply under normal indoor return air applications When a cooling system is installed which uses the furnace blower to provide airflow over the indoor coil the coil m...

Страница 12: ...ncewithNFPAand SMACNAconstructionstandards Consultwithlocalcodes for special requirements For best sound performance be suretoinstallalltheneededgasketsandgrommetsaround penetrations into the furnace...

Страница 13: ...urnace is installed horizontally remove the bottom panel from the furnace before attaching the duct system See Bottom Panel Removal on page 14 If installing the furnace in an attic it is required that...

Страница 14: ...oor 1 from the blower compartment 2 Remove all screws securing the bottom panel 2 to the front brace 3 3 Remove two screws 4 securing the furnace cabinet to the blower deck 5 4 Remove all screws 6 sec...

Страница 15: ...ion of the National Fuel Gas Code ANSI Z223 1 or CAN CGA B149 1 or 2 Installation Codes Some local regulations require the installation of a manual main shut off valve and ground joint union external...

Страница 16: ...ed from the furnace to prevent damage to the gas control valve If the test pressure is less than or equal to 1 2 psig 14 inch W C close the manual shut off valve High Altitude Application High altitud...

Страница 17: ...Plug 8 Shut Off Valve NOTE Some utilities require Shut Off Valve to be 4 to 5 feet above floor Figure 13 Typical Gas Connections 3 4 5 UPFLOW MODELS DOWNFLOW MODELS 8 Right Side Entry Left Side Entry...

Страница 18: ...henconversioniscomplete verifythemanifoldpressure and input rate are correct as listed in theTables Approved conversion kits are listed below The United States LP Propane Gas Sea Level and High Altitu...

Страница 19: ...e in the field supplied disconnect at the furnace Ground Furnace Input Btuh Cabinet Width in Nominal Electrical Supply Maximum Operating Voltage Minimum Operating Voltage Maximum Furnace Amperes Minim...

Страница 20: ...ee Figure 17 Connect the thermostat s W1 W2 outputs to the furnace control board s W1 W2 terminals Always connect the thermostat C R to the furnace control board C R For cooling connect the thermostat...

Страница 21: ...idistat connect the DHUM R terminals on the humidistat to the DHUM R terminals on the motor control board In this option the DHUM output of the humidistat must be set to be normally open and closed wh...

Страница 22: ...y referring to Table 10 page 39 for Propane or Tables 12 or 13 page 40 for Natural Gas c Using an Allen wrench turn the the LO Input Adjusting Screw on the LO side of the regulator to adjust the reduc...

Страница 23: ...door Verifying Operation of the Supply Air Limit Switch A properly functioning limit switch should turn off the gas valve when the return is blocked time depends on how well the return air is blocked...

Страница 24: ...ance from a furnace Follow these instructions for years of safe trouble free operation ELECTRICAL SHOCK FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injur...

Страница 25: ...he gas supply piping at the furnace 7 Remove the piping between the gas valve and the ground joint union If applicable 8 Remove all screws securing the burner assembly to the furnace 9 Carefullyremove...

Страница 26: ...personal injury or death Lubrication The bearings in the blower motor and inducer blower used in these furnaces are pre lubricated and sealed by the manufacturer No further oiling of the bearings is...

Страница 27: ...to determine fault condition IMPORTANT NOTE The furnace will lock out after 5 failed attempts for ignition and will try again every hour if the call for heat remains If the Inducer Blower is operatin...

Страница 28: ...e B Vent Pipe 23 1 1 4 FLANGES T stat 7 8 Electric 7 8 G a s 1 5 8 X 3 1 2 X 4 5 Gas 1 5 8 X 3 1 2 Electric 7 8 FRONT VIEW Front Brace Bottom Panel 34 1 2 28 TK 80 Downflow Furnace Cabinet Size Dim A...

Страница 29: ...56 1 020 58 980 60 1 1 0 1 1 290 46 1 255 47 1 220 49 1 180 50 1 145 52 1 110 53 1 075 55 1 040 57 0 0 1 1 1 315 45 1 275 46 1 240 48 1 200 49 1 160 51 1 120 53 1 085 55 1 045 57 1 0 1 1 1 350 44 1 3...

Страница 30: ...48 1 775 50 1 710 52 1 640 54 1 575 56 1 510 59 1 445 62 0 1 0 1 1 980 45 1 910 47 1 845 48 1 780 50 1 715 52 1 650 54 1 580 56 1 515 59 1 1 0 1 2 025 44 1 960 45 1 895 47 1 830 49 1 765 50 1 700 52 1...

Страница 31: ...VC1 Input BTU 100 000 TA TK 120C VC1 Input BTU 120 000 1 2 3 4 CFM Temp Rise F CFM Temp Rise F 0 0 0 1 000 74 1 000 89 0 0 1 1 115 66 1 115 80 0 1 0 1 230 60 1 230 72 0 1 1 1 345 55 1 345 66 1 0 0 1 4...

Страница 32: ...1 1 1 0 0 980 1 420 1 1 1 0 1 1 020 1 480 1 1 1 1 0 1 065 1 540 1 1 1 1 1 1 105 1 600 TA TK FURNACES with VARIABLE SPEED BLOWERS C CABINET Switch Settings 0 OFF 1 ON CFM Nominal A C HP Capacity HEAT...

Страница 33: ...L1 IN L1 OUT Y1_OUT Y Y2_OUT W_OUT C EXPANSION PORT R RED GREEN NOT FOR FIELD USE CONNECTION TO FURNACE CONTROL BOARD CONNECTION TO IQ THERMOSTAT IF APPLICABLE MOTOR WIRING HARNESS RED INPUT TERMINALS...

Страница 34: ...REEN BROWN BROWN YELLOW VIOLET VIOLET VIOLET ORANGE ORANGE ORANGE VENT LIMIT ON SELECT MODELS BLACK 120V WHITE NEUTRAL GROUND 710916 CONDENSATE ON SELECT MODELS Refer to the Installation Instructions...

Страница 35: ...END 0409 LOW VOLTAGE HIGH VOLTAGE BLUE BLUE BLUE BLUE BLACK BLACK 120V WHITE BLACK BLACK BLACK BLACK BLACK BLACK WHITE WHITE NEUTRAL BLACK WHITE WHITE RED RED GREEN GROUND GREEN BROWN BROWN YELLOW VIO...

Страница 36: ...AL GROUND CONDENSATE ON SELECT MODELS BLACK VIOLET For 80 and 90 2 Stage Variable Speed Upflow Furnaces WIRING DIAGRAM 7109180 FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE Refer to the Installation In...

Страница 37: ...t Flash Off Low Flame Sensor Signal Flame Present Diagnostic Description FAULT CONDITIONS Diagnostic Description Yellow LED Continuous Flash On Alternating Flash Motor Fault On Off 0409 FLAME ROLL OUT...

Страница 38: ...ER REVOLUTION OF GAS METER 1 5 10 10 360 1 800 3 600 12 300 1 500 3 000 14 257 1 286 2 571 16 225 1 125 2 250 18 200 1 000 2 000 20 180 900 1 800 22 164 818 1 636 24 150 750 1 500 26 138 692 1 385 28...

Страница 39: ...RE 6 000 to 7 999 FT 56 56 56 56 56 ORIFICE SIZE 4 2 9 0 4 2 9 0 4 2 9 0 4 2 9 0 4 2 9 0 MANIFOLD PRESSURE 8 000 to 10 000 FT 56 56 56 56 56 ORIFICE SIZE 4 2 8 5 4 2 8 5 4 2 8 5 4 2 8 5 4 2 8 5 MANIFO...

Страница 40: ...000 to 9 999 FT 48 48 48 48 48 ORIFICE SIZE 1 7 2 8 1 7 2 8 1 7 2 8 1 7 2 8 1 7 2 8 MANIFOLD PRESSURE Table 13 High Altitude Deration Chart for Natural Gas Low Heating Value NATURAL GAS with LOW HEAT...

Страница 41: ...h Roll Out Switch Transformer Blower Assembly Furnace Control Board Main Air Limit Switch 1 2 3 4 5 6 7 8 Furnace Control Board Combustion Tube Gas Manifold Gas Valve Inducer Assembly Pressure Switche...

Страница 42: ...42...

Страница 43: ...43...

Страница 44: ...tion of this appliance Some local codes require licensed installation service personnel for this type of equipment Please read all instructions carefully before starting the installation Return these...