14
Bottom Panel Removal
The steps listed below describe how to remove the bottom
panel from the furnace. See Figure 11.
1. Remove the blower door (1) from bottom of furnace.
2. Disconnect the wiring harness (2) from the connector.
3. Remove two screws (3) securing the blower assembly
(4) to the furnace.
4. Carefully pull the blower assembly (4) out thru the front
of the furnace.
5. Remove all screws (5) securing bottom panel (6) to
bottom of furnace and front brace (7).
6. Lift up and slide bottom panel (6) out through front of
furnace.
7. Reinstall the blower assembly (4) in reverse order it
was removed.
Figure 12. Alternate Removal Method
1
4
2
7
3
6
5
Alternate Bottom Panel Removal
If the bottom panel cannot be removed using the previous
instructions, the steps below are an alternate method for
removing the bottom panel. See Figure 12.
1. Remove the door (1) from the blower compartment .
2. Remove all screws securing the bottom panel (2) to the
front brace (3).
3. Remove two screws (4) securing the furnace cabinet
to the blower deck (5).
4. Remove all screws (6) securing the furnace cabinet to
the bottom panel (2).
5. Remove the screw (7) securing the bottom corner of
the furnace cabinet to the front brace (3).
6. Carefully spread the bottom corner of the furnace cabinet
outwards while sliding the bottom panel (2) out through
the front of the furnace.
7. Reassemble the furnace in reverse order.
6
7
5
1
2
3
4
Figure 11. Bottom Panel Removal
Pressure Switches
Figure 10 displays the proper routing
of pressure switch tubing for *TA & *TK
furnaces. On both furnaces, the tubing
connects at one end of the pressure
switch and is routed directly to the
static tap on the inducer assembly.
NOTE:
The control board in the *TA
illustration has been omitted for clarity
of tubing installation. There is no need
to remove the control board to install
your pressure switch tube.
1
2
3
4
5
6
7
8
Figure 10. Pressure Switch Tubing for *TA & *TK Furnaces