Repair
6-5
Part 107016-02
E
2016 Nordson Corporation
Contact Tip Replacement
See Figure 6-3.
1. Perform steps 1 through 4 of the
Powder Path Repair
procedure.
2. Unscrew the old contact tip (1) from the resistor probe (2).
3. Apply dielectric grease to the threads of the new contact tip and in the
end of the probe.
4. Screw the new contact tip into the resistor probe and tighten it securely.
Wipe the excess dielectric grease off the contact tip and probe.
5. Install the wear sleeve over the resistor probe. Install the powder inlet
body, nozzle, and hose adapter.
Содержание Versa-Spray II
Страница 4: ...Change Record ii Part 107016 02 E 2016 Nordson Corporation...
Страница 16: ...Installation 3 4 Part 107016 02 E 2016 Nordson Corporation...
Страница 28: ...Troubleshooting 5 8 Part 107016 02 E 2016 Nordson Corporation...
Страница 42: ...Parts 7 8 Part 107016 02 E 2016 Nordson Corporation...
Страница 56: ...Options 8 14 Part 107016 02 E 2016 Nordson Corporation...