2016 Nordson Corporation
Specifications
Maximum rated output voltage at the electrode 100,000 volts
±
10%
Maximum rated output current at the electrode 0.150 mA
±
10%
This equipment is rated for use in an explosive environment
(Class II, Division I) and Zone 21 or Zone 22.
Air Quality
Powder spray systems require clean, dry, oil-free operating air. Moist or
oil-contaminated air can cause the powder to clog in the pump venturi
throat, feed hose, or powder path.
Use 3-micron filter/separators with automatic drains and a refrigerated or
regenerative desiccant-type air dryer that can produce a 3.4
_
C (38
_
F) or
lower dewpoint at 7 bar (100 psi).