Shutdown
CAUTION:
To prevent coating material failure and damage to the system, do not
operate the pump at a high rpm for long periods of time without actuating the applicators.
Short-Term Shutdown
1.
If used, turn off the fluid heaters 12−15 minutes prior to shutdown. Refer to the heater
manual for procedures.
2. Turn the back pressure regulator knob fully counterclockwise to de-pressurize the
system.
3.
Turn off the EP2 pump.
4.
If used, shut off the pressure feed.
Long-Term Shutdown
CAUTION:
To prevent damage to the fluid diaphragms and seals, consult a Nordson
representative for types of solvents that can be left in the system for long periods of time.
1.
If used, turn off the fluid heaters 12−15 min prior to shutdown. Refer to the heater
manual for procedures.
2. Flush the system with a solvent compatible with the coating material.
3. Turn the back pressure regulator knob fully counterclockwise to de-pressurize the
system.
4.
Turn off the EP2 pump.
5. Remove and clean the applicator nozzles.