© 2021 Nordson Corporation
Pump Oil Level
CAUTION:
To prevent damage to the pump, do not allow the oil to drop below the
recommended level. Use only Nordson EP2 pump oil, part 1049265. Do not use EP1
pump oil, as it will damage the pump.
See Figure 3
. Unscrew the oil fill cap (7) and check the pump oil level . The oil level
should be within 6 mm (1/4 in.) from the top.
Electrical Connections
WARNING:
Electrical installation and wiring must be done by a qualified electrician, and
must conform to all applicable regulations and codes.
WARNING:
Disconnect and lock out power before connecting electrical wiring to the
load switch box. Ground the pump base, load switch box (US versions) and all system
components, including supply and waste containers, to prevent static discharges that
could cause a fire or explosion.
Wiring Guidelines
Motor:
380−420 volt, 3 phase (Wye), 50/60 Hz
• Use electrical wiring sized and rated for use with the motor. All electrical installations
must conform to local regulations and codes.
• Use approved, properly sized, liquid-tight conduit connectors or strain reliefs to bring
wiring into the load switch box.
•
Refer to the wiring diagrams in this manual for proper voltage configuration and wiring
connections.
NOTE:
The pump can rotate in either a clockwise or counterclockwise direction, so
phase wiring order is not critical.
• Connect the pump base ground clamp to a true earth ground.
WARNING:
The load switch must be grounded. Failure to ground the load switch will
create an electrical hazard that could result in severe shock and personal injury.
Содержание EP2
Страница 4: ... 2021 Nordson Corporation 1072608 04 ii Change Record ...
Страница 11: ...7 EP2 Pump System 2021 Nordson Corporation 1072608 04 1 2 3 4 3 5 Figure 1 Safety Label Location ...
Страница 32: ...28 EP2 Pump System 2021 Nordson Corporation 1072608 04 This page is intentionally left blank ...
Страница 38: ...34 EP2 Pump System 2021 Nordson Corporation 1072608 04 ...