27
© 2021 Nordson Corporation
Problem
Possible Cause
Corrective Action
9. Loss of oil
Oil drain plug or fill cap
loose
Tighten the plug and/or cap.
Worn shaft seal
Replace the shaft seal.
Diaphragm screw O-ring
cracked or missing
Replace the O-ring.
Valve plate and end plate
bolts loose
Tighten the bolts to 74−81 N•m (55−60 ft-lb), following the torque
sequence in the EP2 Three-Piston Pump manual.
Damaged diaphragm
cartridges
Replace the diaphragm cartridges.
10. Water or coating
material in oil
reservoir
Diaphragm screw O-ring
cracked or missing
Replace the diaphragm screw O-ring.
Damaged diaphragm
cartridges
Replace the diaphragm cartridges.
Cracked cylinder casting Replace the pump.
Repair
WARNING:
SERVICING - Before servicing, cleaning, or removal of any part, set trigger
lock on gun, and always shut off power source; then carefully release pressure in fluid
portions of the system.
For EP2 pump assembly repair, refer to the pump manual:
EP2 Three-Piston Pump
- Part 1049229
Содержание EP2
Страница 4: ... 2021 Nordson Corporation 1072608 04 ii Change Record ...
Страница 11: ...7 EP2 Pump System 2021 Nordson Corporation 1072608 04 1 2 3 4 3 5 Figure 1 Safety Label Location ...
Страница 32: ...28 EP2 Pump System 2021 Nordson Corporation 1072608 04 This page is intentionally left blank ...